Zero Zone 63-0006Y Genuine OEM Five-Petal Fan Blade
Zero Zone 63-0006Y Genuine OEM Five-Petal Fan Blade is backordered and will ship as soon as it is back in stock.
Delivery and Shipping
Delivery and Shipping
Shipping options and prices are shown at checkout. Please call 631-873-0509 before placing an expedited order. Read our shipping policy.
Description
Description
Product Overview
Genuine OEM Zero Zone part 63-0006Y. Match the complete part number and equipment model/serial record before ordering.
Zero Zone 63-0006Y is a replacement five-petal fan blade for the matching refrigeration fan assembly. This listing is for the blade, not a motor. The full part number and equipment record should establish fit before dimensions or appearance are used as secondary checks.
Verified Part Details
- Manufacturer part number: 63-0006Y.
- Configuration: five-petal fan blade.
- Motor, mounting hardware and other assembly components are not represented as included.
- Verify diameter, hub fit, pitch, rotation reference and installed clearance against the original assembly.
Troubleshooting and Service Checks
Vibration, scraping and poor airflow can come from a bent blade, ice buildup, loose hub, damaged mount or worn motor bearings. Isolate power and inspect the blade and surrounding shroud before handling the assembly. Do not straighten a damaged blade and assume it is balanced. After repair, confirm secure mounting, clearance and the intended airflow direction using the equipment service procedure.
Before You Order
- Verify the cabinet model and serial number against the specified service blade.
- Compare hub attachment and the blade position on the motor shaft.
- Confirm the required rotation with its stated viewing direction.
- Inspect the motor shaft, bearings, guard and mounting before deciding the complete repair scope.
Frequently Asked Questions
How many petals does this blade have?
The exact service record identifies a five-petal blade.
Does 63-0006Y include a fan motor?
No motor is represented as included. Select a motor separately by its verified part number if needed.
Can I choose a blade only by diameter?
No. Hub fit, blade pitch, rotation, clearance and the equipment-approved part number also matter.
What can cause a replacement blade to vibrate?
A damaged blade, incorrect mounting, shaft wear, loose hardware or contact with ice or the shroud can cause vibration.
Can I infer clockwise rotation from a photograph?
No. Rotation needs a defined viewing direction and confirmation from the motor and equipment documentation.
Will replacing the blade solve every weak-airflow complaint?
No. Check motor operation, coil blockage, ice and obstructions as well as blade condition.
Related Parts and Fitment Help
Browse the Zero Zone parts guide or request a part match. Include the full equipment model, serial number and photographs of the original component and its markings.
Reviews (0)
Reviews (0)
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.