Replacement Thermostat for Turbo Air 30283L0100 – 28-1/4" Capillary
Replacement Thermostat for Turbo Air 30283L0100 – 28-1/4" Capillary is backordered and will ship as soon as it is back in stock.
Delivery and Shipping
Delivery and Shipping
Shipping options and prices are shown at checkout. Please call 631-873-0509 before placing an expedited order. Read our shipping policy.
Description
Description
Replacement Thermostat for Turbo Air 30283L0100 with 28-1/4-Inch Capillary
Part classification: Commercial Replacement Part.
Service a compatible commercial refrigeration temperature-control system with the replacement thermostat for Turbo Air 30283L0100. This mechanical control features a 28-1/4-inch capillary tube with a plain sensing end. Match replacement reference 30283L0100, the original control markings and the equipment model and serial number before ordering.
Product Specifications
- Replacement reference: Turbo Air 30283L0100.
- Part type: Mechanical refrigeration thermostat / temperature control.
- Capillary length: 28-1/4 inches.
- Sensing end: Plain end.
- Service-manual control identification: Ranco K55Q-5607.
- Application: Compatible commercial refrigeration equipment.
Documented Equipment Applications
Turbo Air's MST Mega Top service manual identifies thermostat 30283L0100 for the following models:
- MST-28-12
- MST-48-18
- MST-60-24
- MST-72-30
This coverage applies to the configurations documented in that manual. Verify the serial number and existing thermostat before purchase; do not extend this compatibility to newer models or additional model suffixes without confirmation.
Function and Purpose
The thermostat responds to temperature at its sensing location and switches the refrigeration control circuit as cooling is required. Correct sensing-end placement and capillary routing are essential to proper operation. An otherwise matching thermostat may regulate incorrectly if its sensing end is installed in the wrong location.
Common Symptoms to Investigate
- The cabinet runs warmer or colder than its normal operating range.
- Cooling does not respond normally to control adjustments.
- The refrigeration system runs continuously or fails to start.
- The capillary is kinked, crushed or visibly damaged.
These symptoms do not confirm a thermostat failure. Check airflow, condenser cleanliness, door sealing, evaporator condition and the electrical circuit before replacing the control.
Before You Order
- Match replacement reference 30283L0100 and the markings on the original control.
- Record the complete Turbo Air model and serial number.
- Compare capillary length, sensing-end arrangement and routing.
- Check terminal layout, mounting bracket, shaft and knob connection.
- Verify electrical ratings against the installed control and equipment wiring diagram.
Installation and Service
Have a qualified refrigeration technician disconnect and verify power is off before replacement. Document the wiring and original sensing position. Route the new capillary without sharp bends, pinching or contact with moving components.
Do not cut or shorten the sealed capillary tube. After installation, allow the equipment to stabilize and verify temperature with an independent thermometer while checking normal cooling cycles.
Frequently Asked Questions
Which part number does this replace?
This commercial replacement thermostat is listed for Turbo Air part reference 30283L0100. Confirm the model, serial number and original control before ordering.
How long is the capillary tube?
The listed capillary length is 28-1/4 inches, with a plain sensing end.
Which models are documented for this thermostat?
The MST Mega Top service manual lists MST-28-12, MST-48-18, MST-60-24 and MST-72-30. Confirm the serial number and original control for your equipment.
What control marking appears in the service manual?
The manual identifies Ranco K55Q-5607 alongside Turbo Air part number 30283L0100.
Can I shorten the capillary to fit?
No. The capillary is part of the sealed sensing system. Route it according to the equipment instructions without cutting or kinking it.
Does continuous compressor operation mean the thermostat is bad?
Not necessarily. Air leaks, restricted airflow, dirty coils and other refrigeration faults can also cause extended operation. Diagnose the system before replacing parts.
How can I get fitment help?
Call 631-873-0509 with the equipment model and serial number, original thermostat markings and photos of the terminals, mounting and capillary routing.
Related Turbo Air Parts
Browse Turbo Air commercial refrigeration parts for related service components.
Reviews (0)
Reviews (0)
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.