True 831994 Defrost Timer with Bracket, No Enclosure
True 831994 Defrost Timer with Bracket, No Enclosure is backordered and will ship as soon as it is back in stock.
Delivery and Shipping
Delivery and Shipping
Shipping options and prices are shown at checkout. Please call 631-873-0509 before placing an expedited order. Read our shipping policy.
Description
Description
True 831994 Defrost Timer with Bracket, No Enclosure
True 831994 is a replacement DTSX-B-120 defrost timer mounted on a plastic bracket. This service assembly is supplied without an enclosure and replaces True 831913. Select it by the cabinet parts record and timer identification, rather than by the appearance of the dial.
Verified Part Details
- Manufacturer part number: 831994.
- Timer marking: DTSX-B-120.
- Configuration: plastic mounting bracket; enclosure not included.
- Manufacturer-listed predecessor: 831913.
Troubleshooting and Service Checks
A timer that fails to advance, misses a scheduled defrost or remains in defrost warrants circuit testing. Evaporator ice alone does not establish timer failure. A qualified technician should also check heater operation, the termination circuit, wiring and airflow. Isolate electrical power before accessing the assembly; confirm terminal functions from the cabinet diagram before reconnecting wires.
Before You Order
- Match the complete cabinet model and serial number to the required part.
- Compare timer markings, wiring diagram, mounting location and terminal identification.
- Confirm that the original enclosure can be reused and that a bracket-mounted timer is what the repair requires.
- Use the specified cabinet defrost schedule when setting up the replacement.
Frequently Asked Questions
What is True 831994?
It is the replacement DTSX-B-120 defrost timer supplied on a plastic mounting bracket.
Does 831994 include the metal box?
No. This part is the bracket-mounted configuration without an enclosure.
Does it replace timer 831913?
True lists 831994 as the replacement for 831913; confirm the cabinet serial number and wiring arrangement before ordering.
Does evaporator icing prove this timer is bad?
No. Heater, termination-control, airflow and door-sealing problems can also produce icing. Test the defrost sequence first.
Is a matching dial enough to confirm fit?
No. Timer identification, mounting and electrical connections must match the equipment documentation.
What settings should be used after installation?
Use the defrost timing specified for the cabinet. Record existing settings for diagnosis, but do not assume they are correct.