True 800366 Temperature Control Kit, 077B6806
True 800366 Temperature Control Kit, 077B6806 is backordered and will ship as soon as it is back in stock.
Delivery and Shipping
Delivery and Shipping
Shipping options and prices are shown at checkout. Please call 631-873-0509 before placing an expedited order. Read our shipping policy.
Description
Description
Product Overview
True 800366 is a replacement mechanical temperature control kit for specified commercial refrigeration equipment. The manufacturer identifies the control as 077B6806 and the corresponding kit as 077B7172. Its sensing element responds to temperature and operates the matched refrigeration control circuit.
Verified Identification and Contents
- True OEM part number: 800366
- Control identification: 077B6806
- Manufacturer kit reference: 077B7172
- Included with control: Knob and mounting screws
Application Details
True identifies this control as a replacement for 963056 under PCN 7784. If the cabinet was built with a relay, True specifies retrofit kit 882636 instead; verify that distinction before ordering.
Service Symptoms and Checks
Investigate a damaged sensing line, unreliable switching or temperature that does not respond as expected to adjustment. Confirm sensing-element placement and electrical continuity using the service procedure. Airflow restrictions, door-seal problems, relay faults and refrigeration-system problems can produce similar symptoms.
Before You Order
Record the full cabinet model and serial number. Match the original part marking, sensing-line arrangement, mounting and electrical specification. Confirm the required operating range from the cabinet service information. A qualified technician should isolate power and follow the original routing without sharply bending the sensing line.
Commissioning Checks
Keep the sensing line clear of sharp edges and moving components, and preserve its specified contact and routing. After installation, allow the cabinet to stabilize and verify cycling against an independent temperature measurement using the cabinet service procedure. Avoid changing factory calibration to compensate for an unrelated airflow or refrigeration fault.
Frequently Asked Questions
What is the control identification for True 800366?
077B6806 is the control reference, and 077B7172 is the associated kit reference listed by True.
What is supplied with the thermostat?
Knob and mounting screws are listed with the control.
Can I use 800366 on a cabinet originally built with a relay?
True directs those applications to retrofit kit 882636. Check the cabinet’s original electrical configuration before selecting the repair part.
Can I select the replacement from the knob shape?
No. Similar-looking mechanical controls can have different switching characteristics and sensing arrangements. Match the full part number and cabinet specification.
Does an incorrect cabinet temperature prove the control has failed?
No. Check the sensing-element location, airflow, door seal and refrigeration system as well as the control circuit.
What should I send for a fitment check?
Send the complete cabinet model and serial number, the old control marking and photographs of its mounting and sensing-line route.
Related Parts and Fitment Help
Browse the True refrigeration parts guide or ask PartsDirectOnline to check the part match. Send the cabinet data plate and clear photographs of the original component and its markings.
Manufacturer Reference
Reviews (0)
Reviews (0)
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.