Manitowoc 000016053 OEM Water Level Probe Kit with Harness
Need help confirming fitment?
Call 631-873-0509 or send the equipment manufacturer, model number, serial number, and a photo of the old part. Compatibility should be confirmed from verified part data before ordering.
-
Regular price
-
$84.99 USD
-
Sale price
-
$84.99 USD
-
Regular price
-
-
Unit price
- per
Availability : In Stock
Before ordering, compare the part number, measurements, mounting points, voltage, and equipment model. Send us photos and your model/serial number if you want help checking the match.
Check compatibility before ordering
Match the part number, model number, dimensions, and mounting points before checkout. If the part is used across multiple refrigeration units, compare your existing part to the product photos and SKU above.
Refrigeration parts FAQ
How do I confirm this part fits my unit?
Use the SKU, measurements, brand, and product photos to compare against the part currently installed on your refrigerator, freezer, prep table, merchandiser, or ice machine.
Can I order this for a commercial refrigeration repair?
Yes. PartsDirectOnline specializes in commercial refrigeration replacement parts for service companies, restaurants, convenience stores, and maintenance teams.
What should I do if I am unsure about compatibility?
Contact the store with your model number, serial number, photos, and measurements before ordering so the team can help verify the best match.
- Regular price
- $84.99 USD
- Sale price
- $84.99 USD
- Regular price
-
- Unit price
- per
Product Overview
Manitowoc 000016053 OEM Water Level Probe Kit with Harness
The Manitowoc 000016053 Water Level Probe Kit with Harness is an OEM water-level sensing assembly designed for compatible Manitowoc commercial ice machines. The probe works with the machine's control system to provide water-level feedback during the applicable fill and ice-making sequence, while the supplied harness provides the electrical connection required by the original equipment configuration.
Accurate water-level information is critical to dependable commercial ice production. A contaminated, damaged, corroded, incorrectly positioned, or electrically compromised probe can provide unreliable water-level feedback and contribute to abnormal filling, insufficient water, overfilling, inconsistent freeze cycles, or an ice machine that does not progress through its normal operating sequence correctly.
When qualified diagnosis confirms the water-level sensing assembly requires replacement, using the correct Manitowoc OEM 000016053 helps restore the original probe-and-harness configuration intended for compatible Manitowoc Ice equipment.
OEM Part Details
- Manufacturer: Manitowoc Ice
- OEM Part Number: 000016053
- MPN: 000016053
- SKU: 000016053
- Part Type: Water Level Probe Kit with Harness
- Application: Commercial Ice Machines
- System: Water Level / Fill Control System
- Function: Water-Level Sensing & Control Feedback
What the Manitowoc 000016053 Water Level Probe Does
The Manitowoc 000016053 water level probe provides sensing information to the machine's control system so the equipment can respond appropriately to water conditions during operation. The probe and harness work together as part of the control circuit, allowing the machine to receive the water-level information required by its operating sequence.
Proper water-level sensing helps support:
- Reliable water-level detection
- Consistent fill-cycle operation
- Proper water availability for ice production
- Normal freeze-cycle operation
- Reduced overfill or underfill conditions
- Reliable control-system feedback
- Dependable commercial ice production
Probe Kit with Harness
This listing is identified as a water level probe kit with harness. The harness is an important part of the replacement because electrical connector style, lead routing, terminal arrangement, and probe connection can vary between equipment configurations.
Do not select a replacement probe based solely on physical appearance. Verify OEM part number 000016053, the supplied harness arrangement, equipment model, serial number, original connector configuration, mounting position, and machine wiring before ordering.
Common Signs of a Water Level Probe Problem
Qualified commercial ice-machine technicians may inspect the Manitowoc 000016053 when troubleshooting conditions such as:
- Ice machine does not recognize the correct water level
- Machine fills longer than expected
- Water level remains lower than intended
- Machine overfills
- Fill cycle operates intermittently
- Ice production becomes inconsistent
- Machine does not progress through the normal operating sequence
- Probe is coated with scale or mineral deposits
- Probe is corroded or physically damaged
- Harness wiring is damaged
- Connector is loose or corroded
- Probe mounting position has changed
- Machine receives intermittent water-level feedback
These symptoms do not automatically confirm probe failure. Water inlet valves, water pressure, pumps, water distribution components, control boards, wiring, connectors, scale accumulation, and other water-system components can create similar symptoms. The complete water-level and fill system should be diagnosed before replacing the probe kit.
Diagnosing Incorrect Water Level
If a Manitowoc ice machine has too much or too little water, technicians should evaluate the complete water-level system rather than replacing the probe solely based on the symptom.
Depending on the machine configuration, diagnosis may include checking:
- Probe condition
- Probe cleanliness
- Probe mounting position
- Harness and connector condition
- Water inlet valve operation
- Incoming water supply
- Water pressure
- Water pump operation
- Water reservoir condition
- Control-board input and output
- Scale accumulation
- Associated wiring
Testing the complete system helps determine whether the 000016053 itself requires replacement or another water-system component is responsible for the incorrect level condition.
Scale & Mineral Buildup
Water-level probes operate continuously in a wet environment and may be exposed to mineral deposits, scale, and other water-related contamination. Buildup on the sensing area can interfere with accurate water-level feedback.
Technicians should inspect for:
- Mineral deposits
- Scale buildup
- Corrosion
- Sediment
- Water residue
- Contamination around the sensing surface
- Debris around the mounting area
Cleaning and maintenance should follow applicable Manitowoc procedures. If the probe remains unreliable after the complete system has been inspected and serviced, replacement may be required.
Probe vs. Water Inlet Valve Diagnosis
The water level probe and water inlet valve perform different functions. The probe provides water-level feedback, while the inlet valve physically controls water entering the machine.
If the water level is incorrect, both systems may require inspection. A correctly functioning probe cannot compensate for a valve that is restricted or leaking, and replacing the inlet valve will not correct an electrically damaged or contaminated sensing probe.
Probe vs. Water Pump Problems
The water pump circulates water already present within the applicable ice-making system, while the water-level probe monitors the level condition. Poor water circulation and incorrect water level can create overlapping symptoms, so technicians should determine which system is actually responsible.
Inspect the applicable:
- Water level
- Water pump
- Water inlet valve
- Water distribution system
- Probe and harness
- Control-board inputs
Inspect the Harness & Connector
The supplied harness is part of the sensing circuit and should be inspected carefully whenever water-level feedback is intermittent or unreliable.
Look for:
- Loose connector terminals
- Corrosion
- Moisture contamination
- Pinched wiring
- Broken conductors
- Damaged insulation
- Loose crimps
- Connector damage
- Incorrect routing
A damaged harness or poor connection can create the appearance of probe failure even when the sensing element itself is functional.
Technician Checks Before Ordering
Before replacing the Manitowoc 000016053 water level probe kit, verify:
- OEM part number 000016053
- Complete Manitowoc Ice machine model
- Equipment serial number
- Original water-level probe identification
- Original harness configuration
- Probe mounting position
- Probe shape and sensing arrangement
- Connector configuration
- Harness routing
- Associated wiring
- Water inlet valve operation
- Water pump operation
- Scale or contamination around the probe
- Control-board connection
OEM part number, probe configuration, and harness arrangement should be primary identification points. Water-level sensing components can look similar while having different connectors, lead lengths, mounting arrangements, and equipment applications.
Water Quality & Preventive Maintenance
Commercial ice machines operate continuously with facility water, making water quality an important factor in probe reliability. Scale, minerals, sediment, and other deposits can affect water-contact components over time.
When repeated sensing or water-system problems occur, technicians should evaluate:
- Water filtration
- Filter replacement intervals
- Machine cleaning frequency
- Scale accumulation
- Water-system maintenance history
- Incoming water quality
Proper cleaning and water-system maintenance can help support accurate sensing and dependable ice-machine operation.
Commercial Ice Machine Applications
Manitowoc commercial ice machines are used in demanding foodservice environments where accurate water control and reliable ice production are essential.
- Restaurants
- Bars
- Hotels
- Supermarkets
- Convenience stores
- Schools
- Hospitals
- Universities
- Institutional kitchens
- Corporate cafeterias
- Catering operations
- Commercial foodservice facilities
Installation & Service Notes
Disconnect electrical power and follow applicable Manitowoc Ice service procedures before servicing commercial ice-making equipment. Shut off the water supply where required by the service procedure.
Before removing the original 000016053 probe assembly, document the probe position, mounting arrangement, harness routing, connector location, and relationship to surrounding water-system components.
Compare the replacement probe and harness with the original components before installation. Make sure the sensing area is installed in the correct position and that the harness is routed and connected without tension, pinching, or interference.
After installation, restore the equipment to operation and observe the applicable fill and ice-making sequence.
Verify that:
- The probe remains securely mounted
- The harness is properly connected
- Water level is detected correctly
- The fill sequence operates normally
- No intermittent level readings occur
- The machine progresses through its normal operating sequence
- No water leaks or wiring problems are present
Commercial ice-machine sensing and electrical components should be diagnosed and installed by qualified foodservice-equipment service personnel.
Why Correct Manitowoc OEM Identification Matters
Commercial ice-machine water-level probes can appear similar while having different sensing configurations, harnesses, connectors, lead lengths, mounting positions, and machine applications.
Using Manitowoc OEM part number 000016053 together with the supplied harness configuration provides technicians and purchasing departments with strong identification points when comparing the replacement with the original assembly.
Always verify the complete machine model, serial number, original probe, harness, connector, mounting arrangement, and applicable Manitowoc service information before ordering.
Frequently Asked Questions
What is Manitowoc 000016053?
Manitowoc 000016053 is an OEM water level probe kit with harness used in compatible Manitowoc commercial ice machines.
What does the Manitowoc water level probe do?
The probe provides water-level feedback to the machine's control system so the equipment can respond appropriately during its fill and ice-making sequence.
Does Manitowoc 000016053 include a harness?
Yes. This part is identified as a water level probe kit with harness.
Can a bad water level probe cause an ice machine not to make ice?
Yes. Incorrect water-level feedback can interfere with normal machine sequencing and ice production. Other water-system and control components should also be inspected.
Can scale affect the water level probe?
Yes. Mineral buildup and contamination can interfere with water-contact sensing components and should be evaluated during service.
Can a damaged harness cause the same symptoms as a bad probe?
Yes. A loose connector, corroded terminal, broken wire, or damaged harness can interrupt sensing information even when the probe itself is functional.
Can a bad water inlet valve cause incorrect water level?
Yes. A restricted or leaking inlet valve can cause fill problems that may resemble a sensing problem. The valve and probe system should be evaluated together when necessary.
Should the probe position be checked before replacement?
Yes. Incorrect mounting or positioning can affect sensing even when the component is otherwise functional.
Can I replace 000016053 with another probe that looks similar?
No. Verify OEM part number 000016053, harness configuration, connector, mounting position, equipment model, and serial number before ordering.
How do I confirm Manitowoc 000016053 is the correct replacement?
Verify OEM part number 000016053, the complete Manitowoc machine model and serial number, original probe, harness, connector, mounting configuration, and applicable service documentation before ordering.
Is professional installation recommended?
Yes. Commercial ice-machine sensing and control components should be diagnosed and installed by qualified foodservice-equipment service personnel.
Why Buy From Parts Direct Online?
Parts Direct Online supplies OEM commercial ice-machine, refrigeration, and cooking replacement parts for service technicians, contractors, restaurants, hotels, supermarkets, convenience stores, schools, hospitals, institutional kitchens, and foodservice facilities throughout the United States. Our focus is helping commercial equipment professionals identify the correct OEM replacement component and minimize costly equipment downtime.
Key Specifications
- Manufacturer: Manitowoc
- OEM / MPN: 000016053
- Variant SKU: 000016053
- Availability: In stock
Compatibility
Confirm the equipment manufacturer, model number, serial number, installed part number, voltage, dimensions, and mounting points before ordering. Do not assume compatibility from brand alone.
Installation Notes
Compare photos and labels against the old part. Electrical, gas, and fitment-sensitive parts should be installed by qualified service personnel.
Shipping and Returns
Shipping options appear at checkout. Review return eligibility before ordering installed, electrical, or special-fitment parts.
- Regular price
- $84.99 USD
- Sale price
- $84.99 USD
- Regular price
-
- Unit price
- per

0