Commercial Refrigeration & Cooking Equipment Parts | Fast U.S. Shipping | Fitment Help: 631-873-0509

Glastender Parts Lookup Guide

The fastest reliable Glastender parts lookup uses the OEM number together with the equipment model and serial number—or the order number for fabricated underbar equipment. Use this guide to collect the right identifiers, normalize a part-number search, and verify specifications before ordering.

Turn a part-number search into a documented match

Original parts-matching schematic: equipment identity, component markings, then documented fitment.
Original PartsDirectOnline schematic. Illustrates a decision process; not an equipment drawing or a completed repair.
  1. Start with the whole identifier: preserve leading zeros, model suffixes and the full serial or underbar order number. A storefront search finds listings; it does not verify serial compatibility.
  2. Select the correct document: check the manual cover’s model, service orientation and production boundary. F1SB/F1SL changes documentation at serial 290239017; use the refrigeration reference below.
  3. Follow the component to its assembly: record diagram callout, part number and revision. A current part-record description confirms identity but may omit serial coverage.
  4. Resolve discrepancies: if an old number differs, require a manufacturer supersession that covers the equipment and any required kit. Do not assume two similar numbers or different package descriptions mean the same supplied contents.

Measurement example: photograph a gasket beside a ruler, record finished outside width and height without stretching, then photograph the mounting profile and magnet position. For a hinge, include installed handing and center-to-center mounting-hole spacing. A ruler photo supplements the OEM/serial match; it cannot establish fitment by itself.

Request fitment help with the complete tag, component markings, wide installation photo, close connector/profile photo and measurements. For safely inaccessible parts, let the technician obtain the photos.

Refrigeration manual selection: read the full tag first
Equipment / boundary Direct manual and section Diagnosis / ordering use
C1SB, C2SB, C1SL, C1SU; F1SB/F1SL before SN 290239017 OM007 side-serviced coolers and frosters Rev. August 18, 2026. Cover: model/serial scope; printed pp. 2–3: control; p. 5: leveling; p. 6: cleaning.
C1FB, C2FB, C1FL, CP1FB, CP1FL, C1FU, CS1FB, F1FB, F1FL; KC from SN 290187703 / April 15, 2019 OM008 front-serviced coolers and frosters Rev. March 24, 2026. Printed pp. 2–3: control; p. 5: closure and installation; p. 6: cleaning. Confirm the complete cover scope.
F1SB/F1SL starting at SN 290239017 OM014 side-serviced freezers Rev. September 10, 2026. Printed pp. 5–6: control and adaptive/user defrost; p. 7: cleaning. Do not apply the earlier froster settings.
MF24 / MF36 / MF48 built July 8, 2019 onward OM009 mug frosters and plate chillers Rev. March 24, 2026. Printed p. 1: loading; p. 2: controller; p. 4: cleaning/defrost. Earlier units need their own documentation.
Remote back-bar equipment OM002 remote back-bar coolers Consult its model scope and Installation section. Cabinet diagnosis must include the remote installation; a local condenser checklist may not apply.
Replacement controls / probe 07000282 manufacturer record and 06010205 probe record 07000282 digital temperature controller: verify programming and supplied package. The current manufacturer record and older parts-directory packaging descriptions differ; confirm probe inclusion before purchase. A cable length or similar display does not prove fitment.
Glasswasher manuals and parts references
Model / scope Manufacturer reference Use it for / verified catalog connection
GT-18, +1, +1L, +1R, +2, +2-IC, +3; after August 2006 GT-18 manual, rev. March 5, 2026 Printed pp. 2–5: connections, operation and exploded view; p. 12: cleaning; p. 13: symptom chart. Earlier machines require their applicable manual.
GW24 GW24 manual, rev. March 5, 2026 Printed p. 3: component locations; p. 6: panel and cycle; pp. 8–9: cleaning; p. 13: troubleshooting. 01001464 GW24 membrane touchpad is identified by the manufacturer part record.
GD24HT GD24HT installation, operation and service manual Printed pp. 10–13: fill, ready state and shutdown; pp. 17–18: maintenance; pp. 21–25: faults and diagnosis; pp. 26–51: component diagrams. Use its own part numbers, not GW24 substitutions.
Water-inlet valve identification Glastender 01000561 part record 01000561 water inlet solenoid valve. Manufacturer identifies a glasswasher inlet-valve assembly; this record alone does not verify every model/serial application. Match the installed valve and serial lookup before ordering.

1. Find the Glastender model, serial, or order number

Equipment Manufacturer-documented identifier location Capture
Refrigeration Data tag inside the left wall Model, serial, voltage, refrigerant information, complete tag photo
Glasswasher Serial number on the front Model, serial, electrical information, full front and tag photos
Ice cream freezer Serial number on the front Model, serial, electrical and refrigeration information
Underbar fabrication Order-number data sticker on the backsplash Order number, equipment line, length, work height, orientation, full sticker photo

If the tag is dirty or difficult to read, clean only with a method safe for the surface and photograph it with indirect light. Do not rely on a handwritten note when a clear full-tag image is possible.

2. Capture the original part information

  • Record every digit, leading zero, dash, space, prefix, and suffix.
  • Photograph labels before disconnecting wiring or tubing.
  • Record voltage, amperage, wattage, frequency, temperature range, flow rating, or connection size when shown.
  • Measure overall dimensions, mounting-hole spacing, shaft or tube size, and connector style as applicable.
  • Note the component’s location, orientation, wire colors, and surrounding assembly.

Search the exact OEM number first. If no result appears, try a version without spaces or punctuation, but preserve leading zeros. A distributor stock number is not a substitute for a Glastender OEM number.

3. Verify the match before checkout

  1. OEM identity: the listed manufacturer number must match the component or current manufacturer documentation.
  2. Equipment identity: verify the full model, configuration, and serial range when documented.
  3. Function: confirm that the part performs the same role in the same system.
  4. Specifications: compare electrical rating, dimensions, connections, mounting, material, and orientation.
  5. Revision history: check for a documented supersession or required conversion kit.
  6. Safety: use a qualified technician when diagnosis or installation involves electricity, refrigerant, heat, chemicals, or pressurized plumbing.

Production dates, serial breaks, and superseded numbers

A model can remain in service through more than one component revision. Use the full serial number and, when available, the production date to determine which parts list or wiring diagram applies. If a current OEM number replaces a previous number, verify the manufacturer-documented cross-reference and any serial break, conversion kit, connector, or programming requirement; a similar number alone does not establish fitment.

4. Continue by equipment family

Shop available Glastender parts or return to the Glastender Parts Resource Center. For manufacturer records, use Glastender’s official serial-number part finder, parts portal, and manuals library.

Common Glastender ordering mistakes

  • Using the equipment model as though it were the service-part number.
  • Dropping a leading zero or ignoring a suffix, voltage, handing, or connector change.
  • Assuming a previous and current OEM number are interchangeable without a documented supersession.
  • Ordering from a photo before checking serial range, dimensions, mounting, and application.

Information to send when requesting fitment help

  • Full model and serial number, or underbar order number
  • Exact OEM number if visible
  • Complete data-tag and component photos
  • Dimensions, connection details, voltage, and other relevant markings
  • Equipment symptom and the system where the part is installed

Glastender parts lookup FAQ

Where is the serial number on Glastender refrigeration equipment?

Glastender states that the refrigeration model serial number is on the data tag inside the left wall. Photograph the complete tag because model, serial, voltage, and configuration details can all affect fitment.

Where is the Glastender glasswasher serial number?

Glastender states that glasswasher serial numbers are located on the front of the equipment. Use the complete model and serial number when checking parts and manuals.

How are Glastender underbar parts identified?

For underbar equipment, Glastender uses the order number found on the data sticker on the backsplash. The order number helps identify the configured fabricated assembly.

What if the OEM number is unreadable?

Use the model and serial or order number, clear photos, dimensions, connections, electrical markings, and the component location. Do not select a similar-looking part without documented fitment.

Should punctuation or leading zeros be removed from a part number?

Search the exact marking first, then try common spacing or punctuation variations while preserving leading zeros. Confirm the final result against the manufacturer description and specifications.

Can one part fit several Glastender models?

Some service parts are shared, but compatibility must be documented. Cabinet size, service orientation, voltage, temperature application, design revision, and serial range can change the correct part.

Identifier locations and technical scope reviewed against current manufacturer support guidance on 2026-09-15.

Resource update: September 22, 2026. Manufacturer references identify the scope of technical details; diagnostic sequences are editorial guidance and do not represent a completed repair or individual technician review.