Glastender Underbar Equipment Parts Guide
Glastender underbar parts are most reliably identified from the order number on the backsplash data sticker, the installed assembly, and the OEM number on the component. This guide covers parts-selection evidence for sinks, faucets, rinsers, ice bins, drainboards, stations, cabinets, and other fabricated bar equipment.
Understand the equipment before selecting parts
Glastender’s current bar-fabrication families include Choice, Signature, Elevation, and Décor. The broader underbar catalog includes equipment such as sinks, ice bins, drainboards, blender and mixology stations, cabinets, speed rails, waste systems, rinser faucets, and related fabricated assemblies. Similar-looking items may have different dimensions, work heights, finishes, or mounting arrangements.
| System | Examples | Fitment evidence |
|---|---|---|
| Water delivery | Faucets, rinser faucets, valves, aerators, cartridges, tubing | Order number, OEM number, connection size, flow marking, mounting style |
| Drainage | Drains, strainers, waste fittings, tubing, overflow components | Opening diameter, thread or connection, material, assembly location |
| Storage and support | Shelves, clips, pilasters, bottle racks, glassracks | Cabinet dimensions, support profile, material, load application |
| Doors and hardware | Handles, hinges, latches, locks, brackets | Handing, mounting pattern, finish, door or cabinet configuration |
| Fabricated assemblies | Ice-bin, sink, drainboard, rail, and cabinet components | Order number, line, work height, orientation, fabrication drawing |
Common underbar parts and what they do
Faucet, rinser, and water-control parts
Cartridges and valves control flow; aerators shape and limit outlet flow; rinser components direct water to the vessel; and fittings connect the assembly to the supply. A drip or weak spray can be caused by debris, pressure conditions, seals, a damaged cartridge, or restricted plumbing. Verify both the service part and the surrounding water condition.
Drains and waste components
Slow drainage or leakage can originate at a strainer, gasket, drain body, connection, hose, or facility drain. Determine exactly where moisture first appears. Match material, diameter, thread, outlet orientation, and the underbar assembly rather than choosing only by sink opening size.
Cabinet, door, and storage hardware
Hinges, handles, lock components, pilasters, clips, and shelves affect safe access and storage. A sagging door may require alignment or hinge service rather than only a new gasket. Uneven shelving can indicate a bent pilaster or mismatched clip. Current Glastender listings include 06001565 stainless pilaster shelf clips, wire shelves, and several cabinet hardware components.
Stainless fabricated parts
Fabricated components depend on the original equipment line, work height, length, orientation, and options. When the OEM number is not visible, the order number and a dimensioned photo set are especially important. Include overall width, depth, height, hole spacing, drain location, and left/right orientation.
Symptom and inspection guide
| Problem | Inspect | Record before ordering |
|---|---|---|
| Faucet or rinser drips | Cartridge, valve seat, seals, debris, pressure | OEM number, connection, flow mark, photos |
| Weak or uneven spray | Supply, aerator or nozzle, cartridge, restriction | Flow rating, opening size, equipment order number |
| Drain leaks | Strainer, gasket, drain body, tubing, connection | Diameter, thread, outlet direction, material |
| Door or drawer misalignment | Hinges, slides, mounting fasteners, cabinet level | Handing, hole pattern, assembly dimensions |
| Shelf will not sit level | Clip orientation, pilaster, shelf dimensions, cabinet level | Clip profile, pilaster style, shelf size |
Underbar parts ordering checklist
- Photograph the complete backsplash data sticker and record the Glastender order number.
- Identify the equipment line, assembly type, work height, dimensions, and left/right orientation.
- Record the OEM number and all markings on the removed part.
- Measure connections, hole spacing, overall size, and mounting details with the part removed when safe.
- Compare current documentation because build options can change the required part.
Common underbar ordering mistakes
- Using only a sink opening or overall cabinet width instead of the backsplash order number and assembly details.
- Ignoring left/right orientation, work height, connection direction, or mounting-hole spacing.
- Choosing faucet, rinser, or drain components by appearance without matching threads, flow markings, seals, and materials.
- Replacing a shelf clip before confirming the pilaster profile, clip orientation, and shelf size.
Browse Glastender parts, use the lookup guide, or return to the Glastender parts resource center. Manufacturer equipment families are described on Glastender’s official bar-fabrication page.
Glastender underbar parts FAQ
What identifier is used for Glastender underbar equipment?
Glastender advises using the order number for underbar equipment. The order number is found on the data sticker on the backsplash. Photograph the full sticker before requesting parts.
How do I match a Glastender faucet or rinser component?
Compare the OEM number, mounting style, inlet and outlet connections, flow rating when marked, cartridge or valve design, dimensions, and the exact underbar assembly.
Are parts from different Glastender underbar lines interchangeable?
Do not assume so. Choice, Signature, Elevation, and Decor equipment can differ in construction, dimensions, options, and hardware. Use the order number and build documentation.
What causes a rinser or faucet to drip?
Possible causes include debris, a worn cartridge or seal, incorrect water pressure, damaged seating surfaces, or a loose connection. Isolate the water supply and identify the exact component before ordering.
Can stainless underbar equipment be cleaned with chlorine bleach?
Follow the manufacturer’s cleaning instructions. Chlorides and harsh chemicals can damage stainless steel, and cleaning chemicals should never be mixed. Use products and concentrations approved for the equipment.
Technical scope reviewed against current manufacturer categories and support guidance on 2026-09-15. Confirm the exact build and order number before purchasing fabricated components.

0