Commercial Refrigeration & Cooking Equipment Parts | Fast U.S. Shipping | Fitment Help: 631-873-0509

Glastender Underbar Equipment Parts Guide

Glastender underbar parts are most reliably identified from the order number on the backsplash data sticker, the installed assembly, and the OEM number on the component. This guide covers parts-selection evidence for sinks, faucets, rinsers, ice bins, drainboards, stations, cabinets, and other fabricated bar equipment.

Understand the equipment before selecting parts

Glastender’s current bar-fabrication families include Choice, Signature, Elevation, and Décor. The broader underbar catalog includes equipment such as sinks, ice bins, drainboards, blender and mixology stations, cabinets, speed rails, waste systems, rinser faucets, and related fabricated assemblies. Similar-looking items may have different dimensions, work heights, finishes, or mounting arrangements.

System Examples Fitment evidence
Water delivery Faucets, rinser faucets, valves, aerators, cartridges, tubing Order number, OEM number, connection size, flow marking, mounting style
Drainage Drains, strainers, waste fittings, tubing, overflow components Opening diameter, thread or connection, material, assembly location
Storage and support Shelves, clips, pilasters, bottle racks, glassracks Cabinet dimensions, support profile, material, load application
Doors and hardware Handles, hinges, latches, locks, brackets Handing, mounting pattern, finish, door or cabinet configuration
Fabricated assemblies Ice-bin, sink, drainboard, rail, and cabinet components Order number, line, work height, orientation, fabrication drawing

Common underbar parts and what they do

Faucet, rinser, and water-control parts

Cartridges and valves control flow; aerators shape and limit outlet flow; rinser components direct water to the vessel; and fittings connect the assembly to the supply. A drip or weak spray can be caused by debris, pressure conditions, seals, a damaged cartridge, or restricted plumbing. Verify both the service part and the surrounding water condition.

Drains and waste components

Slow drainage or leakage can originate at a strainer, gasket, drain body, connection, hose, or facility drain. Determine exactly where moisture first appears. Match material, diameter, thread, outlet orientation, and the underbar assembly rather than choosing only by sink opening size.

Cabinet, door, and storage hardware

Hinges, handles, lock components, pilasters, clips, and shelves affect safe access and storage. A sagging door may require alignment or hinge service rather than only a new gasket. Uneven shelving can indicate a bent pilaster or mismatched clip. Current Glastender listings include 06001565 stainless pilaster shelf clips, wire shelves, and several cabinet hardware components.

Stainless fabricated parts

Fabricated components depend on the original equipment line, work height, length, orientation, and options. When the OEM number is not visible, the order number and a dimensioned photo set are especially important. Include overall width, depth, height, hole spacing, drain location, and left/right orientation.

Symptom and inspection guide

Problem Inspect Record before ordering
Faucet or rinser drips Cartridge, valve seat, seals, debris, pressure OEM number, connection, flow mark, photos
Weak or uneven spray Supply, aerator or nozzle, cartridge, restriction Flow rating, opening size, equipment order number
Drain leaks Strainer, gasket, drain body, tubing, connection Diameter, thread, outlet direction, material
Door or drawer misalignment Hinges, slides, mounting fasteners, cabinet level Handing, hole pattern, assembly dimensions
Shelf will not sit level Clip orientation, pilaster, shelf dimensions, cabinet level Clip profile, pilaster style, shelf size

Underbar parts ordering checklist

  1. Photograph the complete backsplash data sticker and record the Glastender order number.
  2. Identify the equipment line, assembly type, work height, dimensions, and left/right orientation.
  3. Record the OEM number and all markings on the removed part.
  4. Measure connections, hole spacing, overall size, and mounting details with the part removed when safe.
  5. Compare current documentation because build options can change the required part.

Common underbar ordering mistakes

  • Using only a sink opening or overall cabinet width instead of the backsplash order number and assembly details.
  • Ignoring left/right orientation, work height, connection direction, or mounting-hole spacing.
  • Choosing faucet, rinser, or drain components by appearance without matching threads, flow markings, seals, and materials.
  • Replacing a shelf clip before confirming the pilaster profile, clip orientation, and shelf size.

Browse Glastender parts, use the lookup guide, or return to the Glastender parts resource center. Manufacturer equipment families are described on Glastender’s official bar-fabrication page.

Glastender underbar parts FAQ

What identifier is used for Glastender underbar equipment?

Glastender advises using the order number for underbar equipment. The order number is found on the data sticker on the backsplash. Photograph the full sticker before requesting parts.

How do I match a Glastender faucet or rinser component?

Compare the OEM number, mounting style, inlet and outlet connections, flow rating when marked, cartridge or valve design, dimensions, and the exact underbar assembly.

Are parts from different Glastender underbar lines interchangeable?

Do not assume so. Choice, Signature, Elevation, and Decor equipment can differ in construction, dimensions, options, and hardware. Use the order number and build documentation.

What causes a rinser or faucet to drip?

Possible causes include debris, a worn cartridge or seal, incorrect water pressure, damaged seating surfaces, or a loose connection. Isolate the water supply and identify the exact component before ordering.

Can stainless underbar equipment be cleaned with chlorine bleach?

Follow the manufacturer’s cleaning instructions. Chlorides and harsh chemicals can damage stainless steel, and cleaning chemicals should never be mixed. Use products and concentrations approved for the equipment.