Hoshizaki 3U0111-01 Water Inlet Valve – Ice Machine Replacement
Need help confirming fitment?
Call 631-873-0509 or send the equipment manufacturer, model number, serial number, and a photo of the old part. Compatibility should be confirmed from verified part data before ordering.
-
Regular price
-
$87.99 USD
-
Sale price
-
$87.99 USD
-
Regular price
-
-
Unit price
- per
Availability : In Stock
Before ordering, compare the part number, measurements, mounting points, voltage, and equipment model. Send us photos and your model/serial number if you want help checking the match.
Check compatibility before ordering
Match the part number, model number, dimensions, and mounting points before checkout. If the part is used across multiple refrigeration units, compare your existing part to the product photos and SKU above.
- Regular price
- $87.99 USD
- Sale price
- $87.99 USD
- Regular price
-
- Unit price
- per
Product Overview
Hoshizaki 3U0111-01 OEM Water Inlet Valve
The Hoshizaki 3U0111-01 Water Inlet Valve is an OEM water-control component designed for compatible Hoshizaki commercial ice machines. The valve controls incoming water flow during the applicable machine fill sequence, opening and closing in response to the equipment's control system.
Reliable water delivery is essential to commercial ice production. A water inlet valve that becomes restricted, sticks open or closed, leaks internally, operates intermittently, or develops an electrical problem can contribute to slow filling, insufficient water, excessive water flow, abnormal water levels, inconsistent ice production, or interrupted machine operation.
When qualified diagnosis confirms inlet-valve replacement is required, using the correct Hoshizaki OEM 3U0111-01 helps restore the water-fill configuration intended for compatible Hoshizaki equipment.
OEM Part Details
- Manufacturer: Hoshizaki
- OEM Part Number: 3U0111-01
- MPN: 3U0111-01
- SKU: 3U0111-01
- Part Type: Water Inlet Valve
- Application: Commercial Ice Machines
- System: Water Fill / Water Inlet System
- Function: Controlled Incoming Water Flow
Compatible Hoshizaki Models
The Hoshizaki 3U0111-01 OEM Water Inlet Valve is listed for compatible Hoshizaki commercial ice-machine equipment including:
- CF1A-FS
- CR1A-FS
- KM-1100MAJ
- KM-1100MAJ50
- KM-1100MRJ
- KM-1100MWJ
- KM-1200
- KM-1200MAE
- KM-1200MRE
- KM-1200MWE
- KM-1200SAE
- KM-1200SRE
- KM-1200SWE
- KM-1300MAF
- KM-1300MAH
- KM-1300MRF
- KM-1300MRH
- KM-1300MWF
- KM-1300MWH
- KM-1300NRF
- KM-1300SAF
- KM-1300SAF3
- KM-1300SAH
- KM-1300SAH3
- KM-1300SRF
- KM-1300SRF3
- KM-1300SRH
- KM-1300SRH3
- KM-1300SWF
- KM-1300SWF3
- KM-1300SWH
- KM-1300SWH3
- KM-1301SAJ
- KM-1301SAJ3
- KM-1301SRJ
- KM-1301SRJ3
- KM-1301SWH-P
- KM-1301SWJ
- KM-1301SWJ3
- KM-1340MAJ
- KM-1340MRJ
- KM-1340MRJ3
- KM-1340MWJ
- KM-1600
- KM-1600MRE
Compatibility Note: Hoshizaki equipment can vary by serial number, auxiliary code, production date, and factory configuration. Always verify OEM part number 3U0111-01, the complete machine model, serial number, auxiliary code where applicable, original valve, plumbing arrangement, and electrical connections before ordering.
What the Hoshizaki 3U0111-01 Water Inlet Valve Does
The Hoshizaki 3U0111-01 water inlet valve provides controlled water entry into the applicable ice-machine water system. When commanded by the machine's control circuit, the valve opens to allow water into the equipment. When the fill requirement has been satisfied, the valve closes according to the machine's operating sequence.
Proper inlet-valve operation helps support:
- Controlled incoming water flow
- Consistent water-fill cycles
- Proper water availability for ice production
- Reliable response to the machine control system
- Reduced overfill and underfill conditions
- Consistent freeze-cycle operation
- Dependable commercial ice production
Common Signs of a Water Inlet Valve Problem
Qualified commercial ice-machine technicians may inspect the Hoshizaki 3U0111-01 when troubleshooting conditions such as:
- Ice machine does not fill with water
- Water enters the machine too slowly
- Water level remains lower than expected
- Water continues flowing when the valve should be closed
- Valve does not open when commanded
- Valve operates intermittently
- Fill cycle is inconsistent
- Machine appears to overfill
- Ice production decreases because of insufficient water
- Water leaks from the valve or associated fittings
- Electrical connections are damaged or overheated
- Scale or sediment restricts the valve
- Valve inlet or outlet is obstructed
These symptoms do not automatically confirm valve failure. Water pressure, filters, supply tubing, float switches, water-level probes, control boards, wiring, pumps, and other water-system components can produce similar symptoms. The complete fill system should be diagnosed before replacing the valve.
Diagnosing a Hoshizaki Ice Machine That Will Not Fill
A Hoshizaki machine that does not receive water does not automatically have a failed 3U0111-01 valve. Technicians should first determine whether water is available to the machine and whether the equipment control system is commanding the valve to open.
Diagnosis may include checking:
- Facility water supply
- Water shutoff valve
- Incoming water pressure
- Water filter condition
- Supply tubing
- Valve inlet restriction
- Electrical signal to the valve when commanded
- Valve electrical connection
- Associated wiring
- Float switch or water-level control
- Control-board output
Testing the complete fill circuit helps prevent unnecessary valve replacement when another component is responsible for the no-fill condition.
Diagnosing Water That Will Not Shut Off
If water continues entering the ice machine after the fill command should have ended, technicians should determine whether the valve is mechanically leaking or whether the electrical control system is continuing to command it open.
Possible areas to inspect include:
- Electrical input at the valve when filling should be stopped
- Internal valve sealing condition
- Debris inside the valve
- Mineral or scale accumulation
- Incoming water pressure
- Float-switch operation
- Water-level sensing
- Machine control output
- Associated wiring
Determining whether unwanted water flow is mechanical or control-related helps identify the correct repair.
Water Inlet Valve vs. Float Switch
The water inlet valve and float switch perform different functions within the Hoshizaki water system.
- Water Inlet Valve: Physically controls water entering the machine.
- Float Switch: Provides control feedback associated with water level.
If the machine has an incorrect water level, both components may need inspection. Replacing the inlet valve will not correct a failed water-level sensing component, and replacing the float switch will not correct a valve that is mechanically restricted or leaking.
Water Inlet Valve vs. Water Pump
The inlet valve supplies water to the machine, while the water pump circulates water already present within the applicable ice-making system.
If the machine contains insufficient water, the fill system should be evaluated. If water is present but does not circulate properly, technicians should inspect the water pump and distribution system.
Check the Water Supply Before Replacing the Valve
A restricted facility water supply can create symptoms similar to a failed inlet valve.
Before replacing Hoshizaki 3U0111-01, inspect for:
- Partially closed supply valve
- Restricted water filter
- Low incoming water pressure
- Kinked supply tubing
- Restricted fittings
- Sediment
- Mineral deposits
- Scale accumulation
- Debris at the valve inlet
Correcting upstream restrictions helps ensure the replacement valve receives the water supply required by the machine.
Scale, Minerals & Water Quality
Commercial ice-machine water components operate continuously in contact with facility water. Mineral deposits, sediment, and scale can affect valve operation and water flow over time.
When repeated water-system problems occur, technicians should evaluate:
- Water filtration
- Filter replacement schedule
- Scale accumulation
- Incoming sediment
- Machine cleaning frequency
- Water-system maintenance history
- Supply tubing condition
Proper water-system maintenance can help support reliable fill operation and consistent commercial ice production.
Inspect Wiring & Electrical Connections
If the Hoshizaki 3U0111-01 does not respond when commanded, technicians should inspect the electrical control circuit before replacing the valve.
Look for:
- Loose electrical terminals
- Damaged connectors
- Broken wiring
- Pinched conductors
- Corrosion
- Heat-damaged insulation
- Moisture contamination
- Control-circuit problems
An external wiring or machine-control problem should be corrected before the replacement valve is placed into service.
Technician Checks Before Ordering
Before replacing the Hoshizaki 3U0111-01 water inlet valve, verify:
- OEM part number 3U0111-01
- Complete Hoshizaki machine model
- Equipment serial number
- Auxiliary code where applicable
- Original valve identification
- Equipment electrical requirements
- Electrical connector arrangement
- Water inlet connection
- Water outlet connection
- Valve mounting configuration
- Water-flow direction
- Original plumbing arrangement
- Associated wiring
- Condition of the incoming water system
OEM part-number verification should be the primary identification method. Commercial ice-machine water valves can appear similar while having different electrical requirements, ports, flow characteristics, connectors, mounting arrangements, and machine applications.
Commercial Ice Machine Applications
Compatible Hoshizaki equipment using the 3U0111-01 water inlet valve is commonly installed in demanding commercial environments including:
- Restaurants
- Bars
- Hotels
- Supermarkets
- Convenience stores
- Schools
- Hospitals
- Universities
- Institutional kitchens
- Corporate cafeterias
- Catering operations
- Commercial foodservice facilities
Installation & Service Notes
Disconnect electrical power and shut off the water supply before servicing commercial ice-making equipment. Follow applicable Hoshizaki service procedures.
Before removing the original 3U0111-01 valve, document the electrical connection, water inlet and outlet connections, mounting arrangement, plumbing configuration, and valve orientation.
Compare the replacement valve with the original component before installation. Inspect water tubing, fittings, wiring, connectors, and the supply line for scale, debris, restrictions, or physical damage.
After installation, restore the water supply and inspect all disturbed plumbing connections for leaks. Restore electrical power and operate the machine through the appropriate fill and ice-making sequence.
Verify that the valve:
- Opens when commanded
- Provides normal water flow
- Closes when the fill command ends
- Does not leak at water connections
- Operates without abnormal noise or overheating
- Supports normal machine fill operation
Commercial ice-machine water and electrical controls should be diagnosed and installed by qualified foodservice-equipment service personnel.
Why Correct Hoshizaki OEM Valve Identification Matters
Commercial ice-machine water inlet valves can look nearly identical while having different electrical characteristics, flow requirements, ports, connectors, mounting configurations, and equipment applications.
Using Hoshizaki OEM part number 3U0111-01 together with the verified equipment fitment provides technicians and purchasing departments with strong identification points when comparing the replacement with the original valve.
Always verify the complete equipment model, serial number, auxiliary code where applicable, original valve, water connections, mounting arrangement, and applicable Hoshizaki service information before ordering.
Frequently Asked Questions
What is Hoshizaki 3U0111-01?
Hoshizaki 3U0111-01 is an OEM water inlet valve used in compatible Hoshizaki commercial ice machines.
Which Hoshizaki models use the 3U0111-01 water inlet valve?
The 3U0111-01 is listed for compatible CF1A-FS, CR1A-FS, KM-1100, KM-1200, KM-1300, KM-1301, KM-1340, and KM-1600 equipment, including the exact configurations listed above.
Does Hoshizaki 3U0111-01 fit KM-1100 ice machines?
It is listed for compatible KM-1100MAJ, KM-1100MAJ50, KM-1100MRJ, and KM-1100MWJ equipment.
Does Hoshizaki 3U0111-01 fit KM-1200 equipment?
It is listed for compatible KM-1200, KM-1200MAE, KM-1200MRE, KM-1200MWE, KM-1200SAE, KM-1200SRE, and KM-1200SWE equipment.
Does Hoshizaki 3U0111-01 fit KM-1300 ice machines?
It is listed for numerous compatible KM-1300 configurations including MAF, MAH, MRF, MRH, MWF, MWH, NRF, SAF, SAH, SRF, SRH, SWF, and SWH variants listed above.
Does Hoshizaki 3U0111-01 fit KM-1301 equipment?
It is listed for compatible KM-1301SAJ, KM-1301SAJ3, KM-1301SRJ, KM-1301SRJ3, KM-1301SWH-P, KM-1301SWJ, and KM-1301SWJ3 equipment.
Can a bad water inlet valve cause a Hoshizaki ice machine not to make ice?
Yes. Insufficient incoming water can interrupt normal ice production. Water supply, filters, float switches, water-level controls, wiring, and other fill-system components should also be inspected.
Why won't my Hoshizaki ice machine fill with water?
Possible causes include a restricted water supply, clogged filter, low water pressure, failed inlet valve, electrical problem, water-level control problem, or machine-control issue.
Why does water keep flowing into my Hoshizaki ice machine?
Possible causes include an internally leaking valve, debris preventing the valve from sealing, excessive water pressure, or the machine control system continuing to command the valve open.
Can scale affect the 3U0111-01 water valve?
Yes. Scale, minerals, sediment, and debris can restrict water flow or interfere with internal valve operation.
How do I confirm Hoshizaki 3U0111-01 is the correct replacement?
Verify OEM part number 3U0111-01, the complete Hoshizaki model, serial number, auxiliary code where applicable, original valve, electrical connection, plumbing connections, and mounting configuration before ordering.
Is professional installation recommended?
Yes. Commercial ice-machine water and electrical controls should be diagnosed and installed by qualified foodservice-equipment service personnel.
Why Buy From Parts Direct Online?
Parts Direct Online supplies OEM commercial ice-machine, refrigeration, and cooking replacement parts for service technicians, contractors, restaurants, hotels, supermarkets, convenience stores, schools, hospitals, institutional kitchens, and foodservice facilities throughout the United States. Our focus is helping commercial equipment professionals identify the correct OEM replacement component and minimize costly equipment downtime.
Related Parts and Fitment Help
Key Specifications
- Brand / vendor: Hoshizaki
- Variant SKU: 3U0111-01
- Availability: In stock
Compatibility
Confirm the equipment manufacturer, model number, serial number, installed part number, voltage, dimensions, and mounting points before ordering. Do not assume compatibility from brand alone.
Installation Notes
Compare photos and labels against the old part. Electrical, gas, and fitment-sensitive parts should be installed by qualified service personnel.
Shipping and Returns
Shipping options appear at checkout. Review return eligibility before ordering installed, electrical, or special-fitment parts.
- Regular price
- $87.99 USD
- Sale price
- $87.99 USD
- Regular price
-
- Unit price