Avantco Magnetic Refrigeration Door & Drawer Gaskets – Select Sizes

Regular price $98.25
Shipping calculated at checkout.

Size

Delivery and Shipping

Shipping options and prices are shown at checkout. Please call 631-873-0509 before placing an expedited order. Read our shipping policy.

Description

Avantco Magnetic Refrigeration Door & Drawer Gaskets

Restore proper sealing performance on compatible Avantco commercial refrigeration equipment with a replacement magnetic gasket selected for your specific door or drawer configuration. These replacement seals are intended for commercial refrigerators, freezers, and refrigerated equipment where the dimensions, gasket profile, and mounting method match the original component.

Magnetic refrigeration gaskets help maintain contact between the door or drawer and its mating frame. Replacing a damaged, torn, hardened, or poorly sealing gasket can help reduce unwanted air infiltration, temperature fluctuations, condensation, and unnecessary refrigeration run time.

Important: This product is offered with multiple size options. Dimensions, manufacturer part numbers, installation profiles, and equipment applications may differ by selection. Confirm your exact size and gasket configuration before ordering.

Product Details

  • Equipment Brand: Avantco
  • Product Category: Commercial Refrigeration Gaskets
  • Gasket Type: Magnetic Replacement Seal
  • Mounting: Verify the required dart-in or other retention profile for each option
  • Applications: Compatible commercial refrigerator, freezer, and refrigerated drawer assemblies
  • Available Sizes: Refer to the selected product variant
  • OEM Classification: Verify individually by variant
  • Manufacturer Part Numbers: Confirm the correct number for the selected option

Function and Benefits

A properly fitted magnetic gasket helps create a continuous seal around the refrigerated compartment opening. The flexible gasket material conforms to the mating surface while the embedded magnet provides closing contact where the equipment is designed for a magnetic seal.

  • Helps reduce warm-air infiltration into the refrigerated compartment.
  • Supports consistent cabinet temperature control.
  • Helps reduce condensation caused by damaged door seals.
  • May reduce unnecessary compressor operation associated with air leaks.
  • Provides a replacement option for worn or deteriorated magnetic seals.
  • Supports routine maintenance of commercial refrigeration equipment.

Common Signs of a Damaged Door Gasket

  • Visible tears, splits, or holes in the gasket material.
  • Gasket corners pull away from the door or drawer.
  • Magnetic seal does not contact the frame consistently.
  • Condensation develops around the opening.
  • Frost accumulation appears near a leaking freezer door or drawer.
  • Interior temperature varies or the refrigeration system runs longer than expected.
  • Gasket becomes hardened, brittle, distorted, or permanently compressed.
  • Visible gaps remain when the door or drawer is closed.

Before You Order — Critical Fitment Checks

  1. Identify the equipment manufacturer, model number, and serial number.
  2. Confirm the original manufacturer gasket part number when available.
  3. Select the correct size from the available product variants.
  4. Compare the replacement dimensions with the original gasket using the same measurement method.
  5. Verify the gasket cross-section, magnetic profile, and attachment method.
  6. Determine whether your equipment requires a door gasket or a drawer gasket.
  7. Inspect the existing door, drawer, hinges, and sealing surfaces for alignment problems.
  8. Confirm the selected option is approved or dimensionally appropriate for your specific equipment.

Measurement Note: Gasket measurements may be provided as outside-edge dimensions or dart-center measurements. These methods produce different dimensions for the same gasket. Never rely on approximate width and height alone.

Technician Installation Guidance

Inspect the original gasket and identify how it attaches to the door or drawer. For a verified dart-in installation, carefully remove the existing gasket from its retaining channel and clean the channel before installing the matching replacement profile.

Begin by positioning the new seal correctly around the opening, then seat the retaining dart without stretching or twisting the gasket. Follow the manufacturer's applicable installation instructions and avoid damaging the magnetic insert.

After installation, close the door or drawer and inspect the complete perimeter for continuous gasket contact. Correct any confirmed gasket seating problems and check for door misalignment or worn hinge hardware where necessary.

Technician Troubleshooting

A new gasket may not resolve sealing problems caused by an incorrectly adjusted door, damaged hinge, warped frame, worn drawer slides, or contaminated sealing surface.

Before replacing a gasket, check for mechanical alignment issues and confirm that the existing seal is the source of the air leak.

Frequently Asked Questions

1. What is an Avantco magnetic refrigeration gasket?

It is a replacement sealing component used on compatible commercial refrigeration doors or drawers. The magnetic insert helps the seal maintain contact with its mating surface.

2. Are these genuine OEM Avantco gaskets?

OEM status depends on the individual product variant. Confirm the manufacturer part number and supplied replacement classification before ordering.

3. Will one gasket fit every Avantco refrigerator or freezer?

No. Different models and door or drawer configurations require specific gasket dimensions, profiles, and mounting arrangements.

4. How should I measure my old gasket?

Confirm whether the replacement dimensions refer to the outside edge or mounting-dart centerlines. Measure the existing gasket consistently and compare the profile with the replacement specification.

5. What is a dart-mount gasket?

A dart-mount gasket uses a projecting retaining profile that fits into a corresponding channel. The replacement must have the correct dart dimensions and configuration for the equipment.

6. Can a worn magnetic gasket cause frost or condensation?

Yes. Damaged gasket material or poor sealing contact can allow humid air to enter a refrigerated compartment. Other issues, such as door misalignment or operating conditions, may also contribute.

7. Why is my new gasket not sealing correctly?

Possible causes include an incorrect replacement profile, improperly seated gasket, distorted seal, misaligned door, or damaged mating surface. Inspect the complete perimeter and surrounding hardware.

8. How do I choose the correct size?

Match the equipment model, original OEM part number when available, exact dimensions, gasket profile, and mounting method. Contact PartsDirectOnline for identification assistance when uncertain.

Commercial Refrigeration Gasket Replacement Support

PartsDirectOnline supplies commercial refrigeration replacement gaskets and door hardware for refrigeration technicians, maintenance departments, restaurants, and commercial equipment operators throughout the United States.

For help selecting the correct gasket, provide your equipment model, serial number, original gasket dimensions, and photographs of the gasket profile and mounting channel.

Reviews (0)

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Black Friday Sale · 20% off parts

Use at checkout. One discounted order per customer per day through Monday, November 30.

Apply today’s code