Hobart Magnetic Door Gaskets – Retainer-Mounted Commercial Refrigeration Replacements
Need help confirming fitment?
Call 631-873-0509 or send the equipment manufacturer, model number, serial number, and a photo of the old part. Compatibility should be confirmed from verified part data before ordering.
-
Regular price
-
$44.89 USD
-
Sale price
-
$44.89 USD
-
Regular price
-
-
Unit price
- per
Availability : In Stock
Before ordering, compare the part number, measurements, mounting points, voltage, and equipment model. Send us photos and your model/serial number if you want help checking the match.
Check compatibility before ordering
Match the part number, model number, dimensions, and mounting points before checkout. If the part is used across multiple refrigeration units, compare your existing part to the product photos and SKU above.
- Regular price
- $44.89 USD
- Sale price
- $44.89 USD
- Regular price
-
- Unit price
- per
Product Overview
Hobart Magnetic Door Gaskets – Retainer-Mounted Commercial Refrigeration Replacements
This listing includes 21 retainer-mounted magnetic door gasket options for compatible Hobart commercial refrigeration and foodservice equipment. Available selections vary by overall dimensions, gasket profile, door configuration, equipment application, and individual part reference, so the exact variant should be selected and compared carefully with the gasket being replaced.
These replacement magnetic door gaskets are designed to create a flexible seal between the equipment door and cabinet. The magnetic section helps draw the gasket toward the cabinet surface when the door closes, while the flexible gasket body compresses around the perimeter to help reduce unwanted air infiltration and temperature loss.
This is a multi-variant replacement gasket listing. The 21 available options are not automatically interchangeable. Always use the dimensions, profile, mounting style, equipment model, serial number, and individual variant information when selecting the correct replacement.
Product Details
- Brand Application: Hobart
- Part Type: Magnetic Door Gasket
- Mounting Style: Retainer-Mounted / Push-In
- Seal Type: Magnetic
- Available Options: 21 Gasket Variants
- Application: Commercial Refrigeration & Foodservice Equipment
- Function: Cabinet and door sealing
- Classification: Commercial Replacement Parts
21 Available Gasket Variants
This page combines 21 different gasket selections into one convenient product listing. Individual variants can differ in overall width, height, profile, mounting arrangement, number of sides, and intended equipment application.
Select the required gasket from the available product options and review the exact dimensions and identifying information shown for that variant before ordering.
What a Magnetic Door Gasket Does
A commercial refrigeration door gasket forms a flexible barrier between the equipment door and cabinet opening. When the door closes, the magnetic portion of the gasket helps pull the seal toward the cabinet-facing surface while the flexible profile compresses to close gaps around the perimeter.
A correctly fitted gasket helps limit warm-air infiltration and supports more consistent refrigerated cabinet conditions. A damaged or incorrectly fitted gasket can allow unwanted air and moisture to enter around the door opening.
Retainer-Mounted Push-In Design
The gasket profile used in this product family is designed to secure into the door's gasket retainer or mounting channel. The retaining portion of the gasket presses into the matching channel so the gasket remains positioned around the door perimeter.
The retainer profile is an important fitment point. Two magnetic door gaskets may look nearly identical from the front while using different mounting profiles or overall dimensions.
Common Signs a Door Gasket May Need Replacement
- Gasket is torn, cracked, split, or punctured
- Magnetic section no longer contacts the cabinet evenly
- Gasket has become hard, flattened, or permanently compressed
- Visible gaps appear around the closed door
- Gasket pulls out of the mounting retainer
- Moisture develops around the door opening
- Frost develops around refrigerated door areas
- Door does not seal evenly at the corners
- Cabinet has difficulty maintaining normal temperature
- Original gasket is damaged during door or hinge service
These symptoms do not automatically mean the gasket is the only problem. Worn hinges, door alignment, latch adjustment, damaged retainers, or cabinet damage can also prevent proper sealing.
How to Identify the Correct Gasket
Do not select a commercial refrigerator door gasket based only on appearance. Similar-looking gaskets can have different dimensions, magnetic arrangements, corner construction, mounting profiles, and equipment applications.
Before ordering, compare:
- Equipment manufacturer
- Equipment model number
- Equipment serial number
- Overall gasket width and height
- Gasket cross-section / profile
- Retainer or mounting profile
- Door dimensions and orientation
- Number of gasket sides
- Original gasket corner construction
- Any manufacturer part number available on the original equipment documentation
Measuring the Existing Gasket
Measure the original gasket carefully before selecting one of the 21 variants. Compare the overall dimensions as well as the gasket cross-section and retaining profile.
Commercial refrigeration gasket measurements can sometimes be reported using different measuring points, so dimensions should be combined with the equipment model, serial number, and original part information whenever possible.
Technician Installation Tips
Before installing the replacement gasket, inspect and clean the gasket-retainer channel. Remove dirt, grease, food residue, deteriorated gasket material, and other debris that could prevent the replacement from seating correctly.
Install the gasket evenly around the door without unnecessarily stretching the material. Seat the corners carefully and then work along each side of the door.
After installation, close the door and inspect the complete perimeter. The magnetic gasket should make consistent contact with the cabinet without excessive gaps, twisting, or sections pulling away from the retainer.
If the replacement gasket does not seal evenly, inspect the hinges, latch, door alignment, gasket retainer, and cabinet surface before assuming the gasket itself is incorrect.
Before You Order
This listing contains 21 different gasket variants. The options are not automatically interchangeable.
Before purchasing, confirm:
- Selected gasket variant
- Listed width and height
- Gasket profile
- Retainer / mounting profile
- Equipment model number
- Equipment serial number
- Door size and configuration
- Number of gasket sides when applicable
- Original gasket dimensions and shape
If fitment is uncertain, provide the Hobart equipment model number, serial number, overall gasket dimensions, and clear photos of the original gasket profile before ordering.
Frequently Asked Questions
Are all 21 gaskets on this page the same size?
No. This listing contains 21 different gasket variants. Select the required option and compare its dimensions and profile with the gasket being replaced.
Are all 21 gasket variants interchangeable?
No. Different variants can use different sizes, profiles, door configurations, and equipment applications. Match the individual gasket to the original equipment before ordering.
Are these magnetic door gaskets?
Yes. The gasket design uses a magnetic sealing section to help maintain contact between the gasket and cabinet when the door is closed.
What does retainer-mounted mean?
The gasket has a mounting profile designed to press into a matching gasket channel or retainer around the equipment door.
Can I choose a gasket using dimensions alone?
No. Dimensions are important, but the gasket profile, retaining style, equipment model, serial number, door configuration, and original part information should also be checked.
Why is my Hobart door still not sealing after replacing the gasket?
Possible causes include incorrect gasket fitment, worn hinges, door misalignment, latch adjustment, a damaged gasket retainer, or an uneven cabinet surface.
How do I know which of the 21 gasket variants I need?
Compare the equipment model, serial number, overall gasket measurements, cross-section profile, retaining style, number of sides, and original gasket before selecting the required option.
Commercial Refrigeration Door Gaskets from PartsDirectOnline
PartsDirectOnline supplies commercial refrigeration door gaskets and replacement parts for service technicians, restaurants, commercial kitchens, institutional facilities, maintenance departments, and foodservice operations. Accurate equipment identification, gasket measurements, and profile matching help reduce incorrect orders and improve replacement-part selection.
Key Specifications
- Brand / vendor: Hobart
- Variant SKU: 280984-6
- Availability: In stock
Compatibility
Confirm the equipment manufacturer, model number, serial number, installed part number, voltage, dimensions, and mounting points before ordering. Do not assume compatibility from brand alone.
Installation Notes
Compare photos and labels against the old part. Electrical, gas, and fitment-sensitive parts should be installed by qualified service personnel.
Shipping and Returns
Shipping options appear at checkout. Review return eligibility before ordering installed, electrical, or special-fitment parts.
- Regular price
- $44.89 USD
- Sale price
- $44.89 USD
- Regular price
-
- Unit price
- per