Commercial Refrigeration & Cooking Equipment Parts | Fast U.S. Shipping | Fitment Help: 631-873-0509

HOBART Warmer Cabinet Magnetic Gasket
HOBART Warmer Cabinet Magnetic Gasket

HOBART Warmer Cabinet Magnetic Gasket – OEM-Style Hot Holding Door Seal

Manufacturer PartsDirect
OEM / MPN PD-764-268
Variant SKU PD-764-268
Availability In stock

Need help confirming fitment?

Call 631-873-0509 or send the equipment manufacturer, model number, serial number, and a photo of the old part. Compatibility should be confirmed from verified part data before ordering.

Fast U.S. shipping Expert fitment help before ordering
Regular price
$469.30 USD
Sale price
$469.30 USD
Regular price
Unit price
per 

Availability : In Stock

Need help confirming fitment?

Before ordering, compare the part number, measurements, mounting points, voltage, and equipment model. Send us photos and your model/serial number if you want help checking the match.

Check compatibility before ordering

Match the part number, model number, dimensions, and mounting points before checkout. If the part is used across multiple refrigeration units, compare your existing part to the product photos and SKU above.

Refrigeration parts FAQ

How do I confirm this part fits my unit?

Use the SKU, measurements, brand, and product photos to compare against the part currently installed on your refrigerator, freezer, prep table, merchandiser, or ice machine.

Can I order this for a commercial refrigeration repair?

Yes. PartsDirectOnline specializes in commercial refrigeration replacement parts for service companies, restaurants, convenience stores, and maintenance teams.

What should I do if I am unsure about compatibility?

Contact the store with your model number, serial number, photos, and measurements before ordering so the team can help verify the best match.

Regular price
$469.30 USD
Sale price
$469.30 USD
Regular price
Unit price
per 
Choose Quantity

Product Overview

OEM Part Details

  • OEM Number: PD-764-092
  • OEM Status: VERIFIED
  • MPN: PD-764-092
  • SKU: PD-764-092
  • Part Type: Door Gasket

Product Overview

OEM Part Details OEM Part Number: PD-764-092 MPN: PD-764-092 SKU: PD-764-092 Part Type: Magnetic Door Gasket OEM Status: VERIFIED Product Overview The PD-764-092 magnetic door gasket is a door seal for a commercial warmer cabinet. Positioned around the door perimeter, this gasket helps the door close against the cabinet opening and maintain a consistent seal during normal operation. A dependable seal matters in hot-holding equipment because gaps around the door can allow heat to escape, place added demand on the heating system, and make it harder for the cabinet to maintain its intended holding environment. Door gaskets are wear items that can gradually lose compression, split at the corners, pull away from the mounting area, or become damaged through frequent door use. Replacing a worn gasket can help restore proper door contact and reduce heat leakage at the cabinet opening. The magnetic design helps draw the gasket toward the cabinet frame when the door is closed, while the gasket material provides the compressible barrier between the door and cabinet. Use the verified PD-764-092 part number along with a careful comparison of the removed gasket, door mounting arrangement, and equipment data plate before ordering. Because door seals can appear similar while using different profiles or mounting styles, confirming the original component is an important step in avoiding an incorrect order.

Product Function

Product Function This magnetic door gasket creates a compressible seal between a warmer cabinet door and the cabinet frame. When the door closes, the magnetic portion helps hold the gasket against the mating surface while the gasket body fills minor gaps around the perimeter. This helps limit heat loss through the door opening and supports more consistent operation of the cabinet. The gasket also cushions door contact and helps the door close with proper perimeter contact. A torn, hardened, distorted, or poorly seated gasket can reduce sealing performance, so the condition of the seal should be considered whenever door closure or cabinet heat retention is a concern.

Why Choose a Genuine OEM Replacement?

Why Choose a Genuine OEM Replacement? The verified PD-764-092 OEM part number gives commercial equipment service teams a clear identification point when replacing the door gasket. Matching the original manufacturer part number helps reduce uncertainty created by similar-looking magnetic seals, different gasket profiles, and varying door mounting arrangements. Comparing the removed component with the listed part number and product image supports a more confident order for the intended door-sealing application.

How This Part Works

How This Part Works A magnetic gasket works as the flexible sealing surface around a cabinet door. As the door moves into the closed position, the gasket contacts the cabinet frame and compresses to close off the space between the door and opening. Its magnetic section helps maintain contact with the mating surface, while the gasket material conforms around the perimeter to support an even seal. For the gasket to perform properly, the door must close squarely and the sealing surfaces must meet evenly. Door sag, hinge wear, latch problems, a damaged retainer area, or a twisted gasket can prevent full contact even when the gasket itself is new. The door seal should therefore be evaluated together with the door alignment and mounting condition rather than treated as an isolated component.

Technician Service Tip

Technician Service Tip Before removing the original seal, compare its corner shape, mounting edge, magnetic orientation, and overall door perimeter with the replacement listing. Inspect the door frame contact area, hinge condition, latch action, and gasket mounting channel for damage or misalignment that could affect the new gasket's seal.

Common Failure Symptoms

  • Visible tears, splits, or separated corners in the door gasket may indicate that the seal should be inspected.
  • A door that does not make even contact around the cabinet opening can indicate gasket compression loss or door alignment concerns.
  • Gaps between the gasket and cabinet frame may indicate a distorted, displaced, or damaged seal.
  • Heat escaping around the closed door may indicate that the gasket, hinges, latch, or mating surface needs inspection.
  • A gasket that feels hardened, flattened, or unable to return to shape can indicate normal wear.
  • The door opening unexpectedly easily after closure may indicate reduced magnetic contact or an uneven sealing surface.
  • A gasket that pulls away from its mounting area may indicate damage to the gasket edge or mounting channel.
  • Uneven marks or compressed sections around only part of the gasket may indicate a door alignment or hinge condition that should be checked.
  • Frequent attention to door closure may indicate that the gasket and related door hardware require evaluation.
  • Damage around the door perimeter after heavy cleaning, impact, or repeated use may indicate that the seal should be compared with the original component.

Commercial Applications

Commercial Applications This door gasket is intended for a commercial warmer cabinet door-sealing application. Commercial kitchens, foodservice maintenance teams, restaurant service providers, and equipment repair technicians may encounter this type of wear component during routine door service. In a hot-holding cabinet, the door seal works with the door assembly to help limit heat loss at the cabinet opening when the door is closed. Confirm the equipment data plate, original part number, and original gasket configuration before purchase because equipment-specific fitment has not been provided.

Before You Order

  • Match the OEM part number: Confirm PD-764-092 against the removed component or approved equipment documentation.
  • Compare the original gasket: Review the gasket shape, corner construction, and magnetic sealing edge.
  • Check the mounting style: Confirm how the original gasket attaches to the door before ordering.
  • Review the product image: Compare the pictured gasket with the original component for visual confirmation.
  • Confirm the equipment data plate: Record the equipment model and serial number for service reference.
  • Inspect the door perimeter: Look for damage, distortion, or residue that could affect gasket contact.
  • Check hinge condition: Door sag or uneven alignment can prevent a gasket from sealing evenly.
  • Check latch and closure action: Confirm that the door closes fully against the cabinet frame.
  • Inspect the gasket mounting area: A damaged channel or retainer area may affect installation and seal retention.
  • Compare the complete door arrangement: Confirm that the replacement is being ordered for the same door position and configuration as the removed gasket.

Related Components

  • Door hinges: Inspect hinge wear or looseness because a sagging or misaligned door can prevent even gasket contact.
  • Door latch: Check latch engagement because incomplete closure can leave gaps around an otherwise serviceable gasket.
  • Door closer: Evaluate the closer, where fitted, to confirm the door is being drawn fully into the closed position.
  • Gasket retainer or mounting track: Inspect the gasket mounting area for damage, distortion, or debris that can prevent secure gasket placement.
  • Door frame contact surface: Check the mating surface for damage or buildup that may interfere with an even seal.

Frequently Asked Questions

What is PD-764-092?

PD-764-092 is a verified OEM magnetic door gasket for a commercial warmer cabinet door-sealing application.

What does a magnetic door gasket do on a warmer cabinet?

A magnetic door gasket helps create a compressible seal between the closed door and cabinet frame. This helps limit heat loss around the door opening.

How do I confirm this is the correct door gasket?

Match OEM part number PD-764-092 to the removed component or approved equipment documentation. Also compare the gasket profile, corner shape, mounting style, and door arrangement.

Should I inspect the hinges when replacing a door gasket?

Yes. Worn or loose hinges can cause door sag and uneven gasket contact. Inspect the hinges, latch, door closer, and gasket mounting area when evaluating a door seal.

Can a damaged gasket affect warmer cabinet operation?

A torn, flattened, displaced, or poorly seated gasket can allow heat to escape around the door opening and may make it harder for the cabinet door to maintain an even seal.

Why is the original gasket profile important?

Door gaskets that appear similar can use different mounting edges, corner shapes, and sealing profiles. Comparing the original gasket helps reduce the chance of ordering the wrong part.

Key Specifications

  • Manufacturer: PartsDirect
  • OEM / MPN: PD-764-268
  • Variant SKU: PD-764-268
  • Availability: In stock

Compatibility

Confirm the equipment manufacturer, model number, serial number, installed part number, voltage, dimensions, and mounting points before ordering. Do not assume compatibility from brand alone.

Installation Notes

Compare photos and labels against the old part. Electrical, gas, and fitment-sensitive parts should be installed by qualified service personnel.

Shipping and Returns

Shipping options appear at checkout. Review return eligibility before ordering installed, electrical, or special-fitment parts.

HOBART Warmer Cabinet Magnetic Gasket – OEM-Style Hot Holding Door Seal
Regular price
$469.30 USD
Sale price
$469.30 USD
Regular price
Unit price
per