Commercial Refrigeration & Cooking Equipment Parts | Fast U.S. Shipping | Fitment Help: 631-873-0509

Manitowoc 7627813 OEM Single-Probe Ice Thickness Control
Manitowoc 7627813 OEM Single-Probe Ice Thickness Control

Manitowoc 7627813 OEM Single-Probe Ice Thickness Control

Brand / vendor Manitowoc
SKU 7627813
Variant SKU 7627813
Availability In stock

Need help confirming fitment?

Call 631-873-0509 or send the equipment manufacturer, model number, serial number, and a photo of the old part. Compatibility should be confirmed from verified part data before ordering.

Fast U.S. shipping Expert fitment help before ordering
Regular price
$118.50 USD
Sale price
$118.50 USD
Regular price
Unit price
per 

Availability : In Stock

Need help confirming fitment?

Before ordering, compare the part number, measurements, mounting points, voltage, and equipment model. Send us photos and your model/serial number if you want help checking the match.

Check compatibility before ordering

Match the part number, model number, dimensions, and mounting points before checkout. If the part is used across multiple refrigeration units, compare your existing part to the product photos and SKU above.

Regular price
$118.50 USD
Sale price
$118.50 USD
Regular price
Unit price
per 
Choose Quantity

Product Overview

Manitowoc 7627813 OEM Single-Probe Ice Thickness Control

The Manitowoc 7627813 Ice Thickness Control is an OEM single-probe sensing component designed for compatible Manitowoc commercial ice machines. The control works as part of the machine's ice-production sequence by providing feedback associated with ice thickness at the appropriate point in the operating cycle.

Accurate ice-thickness sensing is important to consistent commercial ice production. A damaged, contaminated, incorrectly positioned, or malfunctioning probe can contribute to abnormal harvest timing, inconsistent ice formation, unusually thick or thin ice, extended operating cycles, or an ice machine that does not progress through its normal sequence as expected.

When qualified diagnosis confirms the ice-thickness control requires replacement, using the correct Manitowoc OEM 7627813 helps restore the sensing configuration intended for compatible Manitowoc equipment.

OEM Part Details

  • Manufacturer: Manitowoc Ice
  • OEM Part Number: 7627813
  • MPN: 7627813
  • SKU: 7627813
  • Part Type: Ice Thickness Control
  • Probe Configuration: Single Probe
  • Application: Commercial Ice Machines
  • System: Ice Thickness / Freeze-Cycle Sensing
  • Function: Ice Thickness Feedback for Machine Control

What the Manitowoc 7627813 Ice Thickness Control Does

The Manitowoc 7627813 single-probe ice thickness control works with the machine's control system to provide sensing feedback associated with ice formation. As the ice machine operates through its freeze cycle, the probe's condition and position allow the equipment to respond according to the applicable Manitowoc operating sequence.

Proper ice-thickness control operation helps support:

  • Consistent ice formation
  • Proper freeze-cycle feedback
  • Reliable transition through the machine operating sequence
  • More consistent ice thickness
  • Reduced abnormal freeze or harvest behavior
  • Dependable commercial ice production
  • Proper interaction with related ice-machine controls

Single-Probe Ice Thickness Control

This listing is specifically identified as a single-probe ice thickness control. Probe configuration is an important replacement detail because Manitowoc ice-machine controls can vary by machine design, production revision, model, and serial number.

Do not select an ice-thickness control based only on general appearance. Verify OEM part number 7627813, probe configuration, connector arrangement, lead routing, mounting method, equipment model, and serial number before ordering.

Common Signs of an Ice Thickness Control Problem

Qualified commercial ice-machine technicians may inspect the Manitowoc 7627813 when troubleshooting conditions such as:

  • Ice forms thicker than expected
  • Ice forms thinner than expected
  • Ice thickness becomes inconsistent between cycles
  • Freeze cycle runs longer than expected
  • Machine does not progress through the normal sequence correctly
  • Harvest timing appears abnormal
  • Probe is physically damaged
  • Probe is bent or incorrectly positioned
  • Scale or mineral buildup is present on the sensing area
  • Probe connection is loose or damaged
  • Lead wiring is damaged
  • Electrical connector shows corrosion or contamination
  • Ice repeatedly forms abnormally near the sensing area

These symptoms do not automatically confirm failure of the 7627813 control. Water distribution, water level, refrigeration performance, control-board operation, probe positioning, scale buildup, wiring, and other ice-machine conditions can create similar symptoms. The complete operating system should be diagnosed before replacing the control.

Probe Position & Alignment Matter

Correct probe positioning is critical to proper ice-thickness sensing. A functional control that is bent, loose, displaced, or installed differently from the original configuration may provide incorrect feedback to the machine.

Technicians should inspect:

  • Probe mounting position
  • Probe alignment
  • Distance from the applicable freezing surface
  • Mounting hardware
  • Physical damage
  • Lead routing
  • Connector seating
  • Evidence of previous adjustment or impact

Before replacing the control, compare the installed probe position with the original Manitowoc equipment configuration and applicable service information.

Scale & Mineral Buildup

Ice-machine sensing components operate in a water-rich environment and may be exposed to mineral deposits, scale, and contamination over time. Buildup around the probe can interfere with normal sensing behavior and should be evaluated during diagnosis.

Inspect for:

  • Mineral scale
  • Water deposits
  • Foodservice-environment contamination
  • Corrosion
  • Debris around the probe
  • Residue affecting the sensing surface

Cleaning and service procedures should follow applicable Manitowoc instructions. If the control is physically damaged or fails appropriate testing after the surrounding system has been inspected, replacement may be required.

Ice Thickness Control vs. Refrigeration Problem

Abnormal ice thickness does not always indicate a failed thickness control. Refrigeration-system conditions can also affect how quickly and evenly ice forms.

Depending on the machine configuration, technicians may need to evaluate:

  • Refrigeration-system performance
  • Water distribution
  • Water level
  • Water pump operation
  • Water inlet operation
  • Freeze-cycle duration
  • Evaporator condition
  • Control-board operation
  • Probe position and condition

Evaluating the complete system helps prevent unnecessary replacement of a functioning probe when another condition is responsible for abnormal ice formation.

Ice Thickness Control vs. Water Distribution Problem

Uneven or incomplete water flow across the freezing surface can create irregular ice formation that may resemble an ice-thickness control problem. Before condemning the 7627813, technicians should verify that water is being distributed correctly during the freeze cycle.

Inspect applicable:

  • Water pump
  • Water distribution components
  • Water passages
  • Water level
  • Scale buildup
  • Restricted tubing
  • Debris in the water system

Inspect Wiring & Connections

A damaged electrical connection can prevent the machine from receiving proper sensing information even when the probe itself is mechanically intact.

Technicians should inspect for:

  • Loose connectors
  • Corroded terminals
  • Damaged lead wires
  • Pinched wiring
  • Broken conductors
  • Moisture contamination
  • Connector damage
  • Evidence of previous improper repair

Any wiring or connection problem should be corrected before a replacement ice-thickness control is placed into service.

Technician Checks Before Ordering

Before replacing the Manitowoc 7627813 ice thickness control, verify:

  • OEM part number 7627813
  • Complete Manitowoc Ice machine model
  • Equipment serial number
  • Original control identification
  • Single-probe configuration
  • Probe shape and arrangement
  • Probe mounting position
  • Lead-wire routing
  • Connector configuration
  • Mounting hardware
  • Related control-board connection
  • Water distribution condition
  • Scale or contamination around the sensing area

OEM part number and probe configuration should be primary identification points. Ice-thickness controls can appear similar while using different probe arrangements, mounting positions, connectors, and machine applications.

Commercial Ice Machine Applications

Manitowoc commercial ice machines are commonly installed in demanding foodservice environments where consistent ice production and dependable control operation are essential.

  • Restaurants
  • Bars
  • Hotels
  • Supermarkets
  • Convenience stores
  • Schools
  • Hospitals
  • Universities
  • Institutional kitchens
  • Corporate cafeterias
  • Catering operations
  • Commercial foodservice facilities

Installation & Service Notes

Disconnect electrical power and follow applicable Manitowoc Ice service procedures before servicing commercial ice-making equipment.

Before removing the original 7627813 control, document the probe position, mounting arrangement, lead-wire routing, connector position, and relationship to the freezing section.

Compare the replacement control with the original component before installation. Do not bend, force, or reposition the probe differently from the intended equipment configuration unless specifically required by Manitowoc service information.

After installation, restore the machine to operation and observe the applicable freeze and harvest sequence.

Verify that:

  • The probe remains securely mounted
  • Lead wiring is properly routed
  • Connections remain secure
  • Ice formation is consistent
  • The machine progresses normally through the freeze cycle
  • Harvest occurs according to the equipment operating sequence
  • No abnormal ice buildup occurs around the sensing area

Commercial ice-machine sensing and electrical controls should be diagnosed and installed by qualified foodservice-equipment service personnel.

Why Correct Manitowoc OEM Identification Matters

Commercial ice-machine thickness controls can look similar while having different probe configurations, mounting arrangements, connectors, lead lengths, control relationships, and machine applications.

Using Manitowoc OEM part number 7627813 together with the identified single-probe configuration provides technicians and purchasing departments with clear identification points when comparing the replacement with the original component.

Always verify the complete machine model, serial number, original control, probe arrangement, connector, mounting configuration, and applicable Manitowoc service information before ordering.

Frequently Asked Questions

What is Manitowoc 7627813?

Manitowoc 7627813 is an OEM single-probe ice thickness control used in compatible Manitowoc commercial ice machines.

What does the Manitowoc ice thickness control do?

The control provides sensing feedback associated with ice thickness so the machine can respond appropriately during its ice-production sequence.

Is Manitowoc 7627813 a single-probe control?

Yes. This listing identifies 7627813 as a single-probe ice thickness control.

Can a bad ice thickness control make ice too thick?

A control or probe problem can contribute to abnormal ice-thickness feedback, but probe position, water distribution, refrigeration performance, scale buildup, and other machine conditions should also be inspected.

Can a bad probe cause thin ice?

Incorrect sensing or probe position can contribute to abnormal cycle behavior, but thin ice can also result from water or refrigeration-system problems. Complete diagnosis is recommended.

Can scale affect the ice thickness probe?

Yes. Mineral buildup or contamination around a sensing component can interfere with normal operation and should be inspected during service.

Why is my Manitowoc freeze cycle taking too long?

Possible causes include sensing problems, refrigeration performance, water distribution, scale buildup, control issues, or other operating conditions. The complete machine should be evaluated before replacing the probe.

Should the probe position be checked before replacement?

Yes. A loose, bent, or incorrectly positioned probe can cause sensing problems even if the control itself is otherwise functional.

Can I replace 7627813 with another Manitowoc ice probe that looks similar?

No. Verify OEM part number 7627813, single-probe configuration, connector, mounting arrangement, machine model, and serial number before ordering.

How do I confirm Manitowoc 7627813 is the correct replacement?

Verify OEM part number 7627813, the complete Manitowoc machine model and serial number, single-probe configuration, original mounting position, connector, wiring arrangement, and applicable service documentation.

Is professional installation recommended?

Yes. Commercial ice-machine sensing and control components should be diagnosed and installed by qualified foodservice-equipment service personnel.

Why Buy From Parts Direct Online?

Parts Direct Online supplies OEM commercial ice-machine, refrigeration, and cooking replacement parts for service technicians, contractors, restaurants, hotels, supermarkets, convenience stores, schools, hospitals, institutional kitchens, and foodservice facilities throughout the United States. Our focus is helping commercial equipment professionals identify the correct OEM replacement component and minimize costly equipment downtime.

Related Parts and Fitment Help

Manitowoc parts · Fitment help.

Key Specifications

  • Brand / vendor: Manitowoc
  • Variant SKU: 7627813
  • Availability: In stock

Compatibility

Confirm the equipment manufacturer, model number, serial number, installed part number, voltage, dimensions, and mounting points before ordering. Do not assume compatibility from brand alone.

Installation Notes

Compare photos and labels against the old part. Electrical, gas, and fitment-sensitive parts should be installed by qualified service personnel.

Shipping and Returns

Shipping options appear at checkout. Review return eligibility before ordering installed, electrical, or special-fitment parts.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Manitowoc 7627813 OEM Single-Probe Ice Thickness Control
Regular price
$118.50 USD
Sale price
$118.50 USD
Regular price
Unit price
per