Traulsen Magnetic Gasket — Push-In Style | Cooler & Freezer Door | 3 or 4-Sided
Need help confirming fitment?
Call 631-873-0509 or send the equipment manufacturer, model number, serial number, and a photo of the old part. Compatibility should be confirmed from verified part data before ordering.
-
Regular price
-
$47.00 USD
-
Sale price
-
$47.00 USD
-
Regular price
-
-
Unit price
- per
Availability : In Stock
Before ordering, compare the part number, measurements, mounting points, voltage, and equipment model. Send us photos and your model/serial number if you want help checking the match.
Check compatibility before ordering
Match the part number, model number, dimensions, and mounting points before checkout. If the part is used across multiple refrigeration units, compare your existing part to the product photos and SKU above.
Refrigeration parts FAQ
How do I confirm this part fits my unit?
Use the SKU, measurements, brand, and product photos to compare against the part currently installed on your refrigerator, freezer, prep table, merchandiser, or ice machine.
Can I order this for a commercial refrigeration repair?
Yes. PartsDirectOnline specializes in commercial refrigeration replacement parts for service companies, restaurants, convenience stores, and maintenance teams.
What should I do if I am unsure about compatibility?
Contact the store with your model number, serial number, photos, and measurements before ordering so the team can help verify the best match.
- Regular price
- $47.00 USD
- Sale price
- $47.00 USD
- Regular price
-
- Unit price
- per
Product Overview
OEM Part Details
- Manufacturer: Traulsen
- OEM Number: 341-38232-00
- OEM Status: VERIFIED
- MPN: 341-38232-00
- SKU: PD-120-254
- Part Type: Door Gasket
Product Overview
Traulsen 341-38232-00 is a magnetic push-in door gasket used to help create a reliable seal around commercial cooler and freezer doors. This gasket supports the door assembly by reducing cabinet air leakage when the door is closed. A sound door seal matters because unwanted warm-air entry can contribute to moisture around the opening, frost accumulation, and added demand on the refrigeration system. The gasket uses a push-in mounting style and magnetic sealing action. Its profile must match the original component and the door channel for the replacement to seat correctly. This is a 3- or 4-sided door gasket configuration, so the original gasket should be compared carefully before ordering. As a wear-related door component, the gasket should be inspected when it becomes torn, hardened, distorted, loose in the channel, or unable to maintain consistent compression against the cabinet face. Using the verified Traulsen OEM number 341-38232-00 helps identify the correct replacement component for applicable equipment. Proper identification also helps avoid ordering a gasket with the wrong profile, mounting style, or door arrangement.
Product Function
This Traulsen door gasket helps seal the space between the door and cabinet opening on commercial refrigeration equipment. The magnetic portion helps hold the gasket against the cabinet surface when the door closes, while the push-in section anchors the gasket in the door channel. Together, these features support consistent door closure and help limit air movement through the door perimeter. A gasket in good condition supports cabinet service by helping preserve the intended door seal. When the seal is compromised, the door assembly, hinges, latch, and gasket channel should all be evaluated because alignment or mounting issues can affect gasket compression.
Why Choose a Genuine OEM Replacement?
This Traulsen OEM door gasket is identified by manufacturer part number 341-38232-00. Matching the verified OEM number helps ensure the replacement is selected by the original part identification rather than by appearance alone. Door gaskets can look similar while using different mounting profiles, magnetic arrangements, or door configurations. Using the correct Traulsen part number provides a clear reference when comparing the original component before purchase.
How This Part Works
When the door closes, the magnetic section of the gasket is drawn toward the cabinet face and the flexible gasket material compresses around the door perimeter. That contact helps form a barrier between the refrigerated cabinet space and the surrounding room air. The push-in mounting section holds the gasket in its door channel so the sealing edge can remain positioned correctly during normal door use. Gasket performance depends on more than the gasket itself. A clean, secure channel helps retain the mounting section, while properly aligned hinges and latching hardware help the door close squarely against the cabinet. If the door is sagging, not closing evenly, or has a damaged sealing surface, a replacement gasket alone may not correct the condition. Inspecting the complete door assembly helps identify conditions that may affect the new gasket's compression.
Technician Service Tip
Before replacing a door gasket, compare the original gasket profile, push-in mounting section, corner arrangement, and overall door configuration with the replacement. Inspect the door channel for debris or damage and evaluate hinge and latch condition if the door does not close evenly.
Common Failure Symptoms
- Tears, splits, or missing sections of the gasket may indicate that replacement is needed.
- A door that does not seal evenly around its perimeter may indicate gasket compression loss or door alignment concerns.
- Visible gaps between the door gasket and cabinet face should be inspected.
- Moisture near the door opening can indicate air leakage through a damaged or poorly seated gasket.
- Frost near the door frame may indicate that the door seal should be evaluated.
- A gasket that feels hardened, flattened, or permanently distorted may no longer provide consistent compression.
- A gasket pulling out of the door channel can indicate wear or damage at the push-in mounting section or channel.
- A door that must be pushed firmly to remain closed may indicate that the gasket, hinges, latch, or cabinet contact surface should be inspected.
- Uneven magnetic contact around the door may indicate a gasket profile, mounting, or door alignment concern.
Commercial Applications
This Traulsen magnetic door gasket is used in commercial refrigeration door service where the verified 341-38232-00 part number applies. Commercial refrigeration environments can include restaurant kitchens, institutional foodservice operations, commercial cold storage areas, and equipment service departments responsible for cooler and freezer cabinets. Door gaskets are routine wear components in high-use cabinet service because frequent door openings, cleaning, impacts, and long-term compression can affect the seal. Equipment-specific fitment is not stated here. Confirm the original Traulsen part number, door arrangement, and equipment identification before ordering. A correct gasket selection helps service teams address door-sealing concerns without relying on visual similarity alone.
Before You Order
- Match Traulsen OEM part number 341-38232-00 to the original component or approved equipment documentation.
- Compare the original gasket profile with the replacement profile.
- Confirm that the original gasket uses a push-in mounting style.
- Compare the original door configuration to confirm whether a 3- or 4-sided gasket arrangement is required.
- Review the product image against the original gasket before purchase.
- Confirm the Traulsen equipment identification and serial information.
- Inspect the door channel to confirm it can securely retain the push-in mounting section.
- Check door hinge alignment and latch condition, since poor alignment can affect gasket compression.
- Inspect the cabinet contact surface for damage, debris, or conditions that may prevent an even seal.
Related Components
- Door hinges should be inspected because hinge wear or misalignment can prevent the door from closing squarely against the gasket.
- Door latch components should be inspected because insufficient latching can reduce gasket compression and allow gaps at the door perimeter.
- Door closer components should be evaluated where present because they help bring the door into its closed position for proper magnetic contact.
- The gasket retainer or door channel should be inspected because damage or debris can prevent the push-in mounting section from seating securely.
- The cabinet door contact surface should be checked because dents, damage, or buildup can interfere with an even gasket seal.
Frequently Asked Questions
What is Traulsen OEM part 341-38232-00?
Traulsen OEM part 341-38232-00 is a magnetic push-in door gasket used for door sealing in commercial refrigeration equipment. Its push-in mounting section is intended to seat in the door gasket channel, while the magnetic portion helps the closed door seal against the cabinet.
What does the magnetic section of this Traulsen door gasket do?
The magnetic section helps draw the door gasket against the cabinet opening when the door closes. A consistent seal helps limit cabinet air leakage around the door perimeter and supports normal commercial refrigeration operation.
What does push-in style mean on Traulsen 341-38232-00?
Push-in style describes the gasket mounting design. The mounting section presses into the door channel rather than using a different attachment method. Compare the original gasket profile and its mounting section carefully before ordering.
What signs may indicate that a commercial refrigeration door gasket needs attention?
Tears, hardened material, flattened compression areas, visible gaps around a closed door, moisture near the door opening, or frost buildup may indicate the gasket should be inspected. Door alignment and related hardware can also affect the seal.
How can I verify Traulsen 341-38232-00 is the correct door gasket?
Match Traulsen OEM number 341-38232-00 to the original component, then compare the magnetic gasket profile, push-in mounting style, door configuration, and equipment model and serial number. Review the existing door channel for a matching installation arrangement.
Should door hinges and latch hardware be inspected when replacing this gasket?
Yes. Worn hinges, latch components, or a misaligned door can keep a new Traulsen magnetic door gasket from making even contact around the cabinet opening. Inspect the door position, closing action, and gasket channel along with the original gasket.
Key Specifications
- Manufacturer: Traulsen
- OEM / MPN: PD-120-254
- Variant SKU: PD-120-254
- Availability: In stock
Compatibility
Confirm the equipment manufacturer, model number, serial number, installed part number, voltage, dimensions, and mounting points before ordering. Do not assume compatibility from brand alone.
Installation Notes
Compare photos and labels against the old part. Electrical, gas, and fitment-sensitive parts should be installed by qualified service personnel.
Shipping and Returns
Shipping options appear at checkout. Review return eligibility before ordering installed, electrical, or special-fitment parts.
- Regular price
- $47.00 USD
- Sale price
- $47.00 USD
- Regular price
-
- Unit price
- per

0