{"product_id":"turbo-air-g8r4500102-evaporator-coil","title":"Turbo Air G8R4500102 OEM Evaporator Coil – M3F726 M3R723 M3R726","description":"\u003ch2\u003eTurbo Air G8R4500102 OEM Evaporator Coil – M3F47 \/ M3R72\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTurbo Air G8R4500102 Evaporator Coil\u003c\/strong\u003e is a genuine OEM commercial refrigeration replacement coil for compatible \u003cstrong\u003eTurbo Air M3F47 and M3R72 series\u003c\/strong\u003e equipment. This evaporator coil is the heat-transfer component located on the low-temperature side of the refrigeration system, where refrigerant absorbs heat from the refrigerated cabinet.\u003c\/p\u003e\n\n\u003cp\u003eFor technicians, restaurants, commercial kitchens, and foodservice facilities searching for a \u003cstrong\u003eTurbo Air M3F47 evaporator coil\u003c\/strong\u003e, \u003cstrong\u003eTurbo Air M3R72 evaporator coil\u003c\/strong\u003e, or \u003cstrong\u003eG8R4500102 replacement coil\u003c\/strong\u003e, the OEM manufacturer part number should be the primary identification reference before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eVerified compatible model references include M3F726, M3R723, and M3R726.\u003c\/strong\u003e Always confirm the complete Turbo Air model, serial number, original coil, dimensions, refrigerant connections, and mounting configuration before installation.\u003c\/p\u003e\n\n\u003ch2\u003eOEM Part Details\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Turbo Air\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e G8R4500102\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Evaporator Coil\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Type:\u003c\/strong\u003e Commercial Refrigerator \/ Freezer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Family:\u003c\/strong\u003e Turbo Air M3F47 \/ M3R72 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Dimensions:\u003c\/strong\u003e 4-1\/4\" x 8-5\/8\" x 33-1\/2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinned Dimensions:\u003c\/strong\u003e 4-1\/4\" x 7\" x 29-1\/2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Commercial Refrigeration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Refrigerant-to-Air Heat Transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible Turbo Air Models\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTurbo Air G8R4500102 OEM Evaporator Coil\u003c\/strong\u003e is listed for compatible Turbo Air refrigeration equipment including:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eM3F726\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM3R723\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eM3R726\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThese model references correspond to Turbo Air M3F47 \/ M3R72 family applications. Equipment configurations can vary by production date and serial number, so model identification alone should not replace OEM part-number and serial-number verification.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBefore ordering:\u003c\/strong\u003e verify \u003cstrong\u003eG8R4500102\u003c\/strong\u003e against the original evaporator coil and confirm the complete Turbo Air equipment model, serial number, coil dimensions, refrigerant connections, and mounting arrangement.\u003c\/p\u003e\n\n\u003ch2\u003eWhat the Turbo Air G8R4500102 Evaporator Coil Does\u003c\/h2\u003e\n\n\u003cp\u003eThe evaporator coil is one of the primary heat-transfer components in a commercial refrigeration system. Low-pressure refrigerant enters the evaporator circuit and absorbs heat from air moving across the coil surface. The refrigeration system then carries that absorbed heat away from the refrigerated cabinet.\u003c\/p\u003e\n\n\u003cp\u003eWhen the G8R4500102 evaporator coil and surrounding refrigeration system are operating correctly, the assembly helps support:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eHeat removal from the refrigerated cabinet\u003c\/li\u003e\n\u003cli\u003eConsistent cabinet temperature\u003c\/li\u003e\n\u003cli\u003eProper evaporator heat transfer\u003c\/li\u003e\n\u003cli\u003eNormal refrigeration-system operation\u003c\/li\u003e\n\u003cli\u003eConsistent airflow across the evaporator section\u003c\/li\u003e\n\u003cli\u003eTemperature recovery following door openings\u003c\/li\u003e\n\u003cli\u003eReliable commercial refrigerator or freezer performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTurbo Air G8R4500102 Dimensions\u003c\/h2\u003e\n\n\u003cp\u003eCorrect dimensions are important when identifying an evaporator coil because similar-looking refrigeration coils can use different mounting arrangements, tubing configurations, and overall dimensions.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Dimensions:\u003c\/strong\u003e 4-1\/4\" x 8-5\/8\" x 33-1\/2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinned Coil Dimensions:\u003c\/strong\u003e 4-1\/4\" x 7\" x 29-1\/2\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCompare these measurements with the original coil before ordering. Dimensions should be used together with OEM part number \u003cstrong\u003eG8R4500102\u003c\/strong\u003e, equipment model, serial number, and connection configuration.\u003c\/p\u003e\n\n\u003ch2\u003eCommon Signs of an Evaporator Coil Problem\u003c\/h2\u003e\n\n\u003cp\u003eA damaged or leaking evaporator coil can affect the refrigeration system's ability to maintain the intended cabinet temperature. Qualified refrigeration technicians may evaluate the G8R4500102 evaporator section when troubleshooting conditions such as:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCabinet temperature remains warmer than intended\u003c\/li\u003e\n\u003cli\u003eEquipment takes unusually long to pull down to temperature\u003c\/li\u003e\n\u003cli\u003eCompressor runs for extended periods\u003c\/li\u003e\n\u003cli\u003eRefrigeration performance gradually declines\u003c\/li\u003e\n\u003cli\u003eUneven evaporator frost pattern\u003c\/li\u003e\n\u003cli\u003eLocalized ice accumulation on the evaporator\u003c\/li\u003e\n\u003cli\u003eVisible corrosion or physical coil damage\u003c\/li\u003e\n\u003cli\u003eBent or heavily damaged coil fins\u003c\/li\u003e\n\u003cli\u003eOil residue appears around tubing or coil connections\u003c\/li\u003e\n\u003cli\u003eRefrigerant leak is confirmed at the evaporator\u003c\/li\u003e\n\u003cli\u003eSystem repeatedly loses refrigerant charge\u003c\/li\u003e\n\u003cli\u003eAirflow through the evaporator section is restricted\u003c\/li\u003e\n\u003cli\u003eCabinet temperature recovery becomes unusually slow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThese symptoms do \u003cstrong\u003enot\u003c\/strong\u003e automatically confirm evaporator coil failure. Fan motors, defrost components, refrigerant charge, restrictions, door gaskets, temperature controls, compressors, condenser conditions, and other refrigeration components can create similar symptoms.\u003c\/p\u003e\n\n\u003ch2\u003eDoes Frost on the Evaporator Mean the Coil Is Bad?\u003c\/h2\u003e\n\n\u003cp\u003eNo. Frost or ice on the evaporator does not automatically mean the G8R4500102 coil requires replacement.\u003c\/p\u003e\n\n\u003cp\u003eExcessive evaporator icing can also be caused by:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eDefrost-system problems\u003c\/li\u003e\n\u003cli\u003eFailed or weak evaporator fan motors\u003c\/li\u003e\n\u003cli\u003eRestricted airflow\u003c\/li\u003e\n\u003cli\u003eDoor gasket leaks\u003c\/li\u003e\n\u003cli\u003eDoors being left open\u003c\/li\u003e\n\u003cli\u003eDrainage problems\u003c\/li\u003e\n\u003cli\u003eTemperature-control problems\u003c\/li\u003e\n\u003cli\u003eSensor problems\u003c\/li\u003e\n\u003cli\u003eAir infiltration into the cabinet\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe frost pattern and complete refrigeration system should be evaluated before replacing the evaporator coil.\u003c\/p\u003e\n\n\u003ch2\u003eHow Technicians Diagnose an Evaporator Coil\u003c\/h2\u003e\n\n\u003cp\u003eQualified commercial refrigeration diagnosis should determine whether the evaporator coil itself is damaged or whether another system condition is responsible for poor cooling.\u003c\/p\u003e\n\n\u003cp\u003eDepending on the symptoms, technicians may evaluate:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eEvaporator frost pattern\u003c\/li\u003e\n\u003cli\u003eSystem pressures\u003c\/li\u003e\n\u003cli\u003eSuperheat\u003c\/li\u003e\n\u003cli\u003eSubcooling\u003c\/li\u003e\n\u003cli\u003eRefrigerant charge\u003c\/li\u003e\n\u003cli\u003eLeak-test results\u003c\/li\u003e\n\u003cli\u003eEvaporator airflow\u003c\/li\u003e\n\u003cli\u003eFan motor operation\u003c\/li\u003e\n\u003cli\u003eDefrost-system operation\u003c\/li\u003e\n\u003cli\u003eTemperature controls and sensors\u003c\/li\u003e\n\u003cli\u003eCompressor performance\u003c\/li\u003e\n\u003cli\u003eCondenser cleanliness and airflow\u003c\/li\u003e\n\u003cli\u003eDoor gasket condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAccurate diagnosis is important because replacing an evaporator coil requires opening the sealed refrigeration system and should only be performed when coil replacement is justified.\u003c\/p\u003e\n\n\u003ch2\u003eSigns of a Refrigerant Leak at the Evaporator Coil\u003c\/h2\u003e\n\n\u003cp\u003eOne reason an evaporator coil may require replacement is a confirmed refrigerant leak. Possible indicators include:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eOil residue on or around the evaporator tubing\u003c\/li\u003e\n\u003cli\u003eRepeated refrigerant loss\u003c\/li\u003e\n\u003cli\u003eLow system pressures\u003c\/li\u003e\n\u003cli\u003eIncomplete evaporator frost pattern\u003c\/li\u003e\n\u003cli\u003eReduced refrigeration capacity\u003c\/li\u003e\n\u003cli\u003eExtended compressor run time\u003c\/li\u003e\n\u003cli\u003eConfirmed electronic or pressure leak-test results\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eRefrigerant loss should be diagnosed by qualified refrigeration personnel. Do not assume the evaporator is leaking based only on poor cabinet temperature.\u003c\/p\u003e\n\n\u003ch2\u003eInspect the Evaporator Fan System\u003c\/h2\u003e\n\n\u003cp\u003eThe G8R4500102 coil depends on adequate airflow for effective heat transfer. Even a properly functioning evaporator coil cannot perform correctly when airflow is severely restricted.\u003c\/p\u003e\n\n\u003cp\u003eInspect applicable airflow components including:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eEvaporator fan motors\u003c\/li\u003e\n\u003cli\u003eFan blades\u003c\/li\u003e\n\u003cli\u003eFan guards and shrouds\u003c\/li\u003e\n\u003cli\u003eAir passages\u003c\/li\u003e\n\u003cli\u003eEvaporator fins\u003c\/li\u003e\n\u003cli\u003eIce accumulation\u003c\/li\u003e\n\u003cli\u003eProduct blocking cabinet airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCorrect airflow problems before concluding that the evaporator coil itself is responsible for poor refrigeration performance.\u003c\/p\u003e\n\n\u003ch2\u003eInspect the Defrost System\u003c\/h2\u003e\n\n\u003cp\u003eExcessive ice accumulation around an evaporator can significantly reduce airflow and heat transfer. Depending on the Turbo Air model, technicians should evaluate applicable defrost components when abnormal icing is present.\u003c\/p\u003e\n\n\u003cp\u003eInspection may include:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eDefrost controls\u003c\/li\u003e\n\u003cli\u003eDefrost heaters where applicable\u003c\/li\u003e\n\u003cli\u003eDefrost sensors\u003c\/li\u003e\n\u003cli\u003eTermination controls\u003c\/li\u003e\n\u003cli\u003eEvaporator fan operation\u003c\/li\u003e\n\u003cli\u003eDrain pan and drain path\u003c\/li\u003e\n\u003cli\u003eControl-board operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eA defrost problem should be corrected rather than replacing a functional evaporator coil.\u003c\/p\u003e\n\n\u003ch2\u003eBefore You Order Turbo Air G8R4500102\u003c\/h2\u003e\n\n\u003cp\u003eBecause evaporator coil replacement requires sealed-system service, carefully verify the replacement before ordering.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eConfirm OEM part number \u003cstrong\u003eG8R4500102\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eConfirm the complete Turbo Air equipment model\u003c\/li\u003e\n\u003cli\u003eConfirm the equipment serial number\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with \u003cstrong\u003eM3F726, M3R723, or M3R726\u003c\/strong\u003e where applicable\u003c\/li\u003e\n\u003cli\u003eCompare the original coil with the replacement image\u003c\/li\u003e\n\u003cli\u003eVerify overall dimensions: \u003cstrong\u003e4-1\/4\" x 8-5\/8\" x 33-1\/2\"\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eVerify finned dimensions: \u003cstrong\u003e4-1\/4\" x 7\" x 29-1\/2\"\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompare refrigerant tubing connection locations\u003c\/li\u003e\n\u003cli\u003eCompare tubing configuration\u003c\/li\u003e\n\u003cli\u003eVerify mounting points and orientation\u003c\/li\u003e\n\u003cli\u003eInspect related fan, defrost, and drainage components\u003c\/li\u003e\n\u003cli\u003eConfirm that qualified sealed-system service is available for installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEvaporator Coil Replacement \u0026amp; Sealed-System Service\u003c\/h2\u003e\n\n\u003cp\u003eThe Turbo Air G8R4500102 is part of the sealed refrigeration circuit. Replacement typically requires professional refrigeration procedures including refrigerant recovery, removal of the original coil, installation of the replacement, brazing or connection work as applicable, pressure testing, leak testing, evacuation, and restoring the proper refrigerant charge.\u003c\/p\u003e\n\n\u003cp\u003eAfter replacement, the refrigeration system should be operated and evaluated to verify proper cooling performance, evaporator frost pattern, system pressures, superheat, airflow, and final cabinet temperature.\u003c\/p\u003e\n\n\u003cp\u003eSealed-system work should be performed by qualified commercial refrigeration personnel using appropriate procedures and equipment.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Choose the Correct Turbo Air OEM Evaporator Coil?\u003c\/h2\u003e\n\n\u003cp\u003eEvaporator coils can appear similar while differing in tubing layout, connection locations, dimensions, fin configuration, mounting points, and refrigeration application.\u003c\/p\u003e\n\n\u003cp\u003eUsing \u003cstrong\u003eTurbo Air OEM part number G8R4500102\u003c\/strong\u003e as the primary identification reference helps technicians, purchasing departments, restaurants, and facility managers select the intended replacement rather than relying on appearance alone.\u003c\/p\u003e\n\n\u003cp\u003eThe combination of \u003cstrong\u003eG8R4500102\u003c\/strong\u003e, the Turbo Air equipment model, serial number, dimensions, and original coil configuration provides the strongest basis for accurate replacement-part identification.\u003c\/p\u003e\n\n\u003ch2\u003eCommercial Applications\u003c\/h2\u003e\n\n\u003cp\u003eThe Turbo Air G8R4500102 evaporator coil is intended for compatible commercial refrigeration equipment used in professional foodservice and cold-storage environments such as:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eSupermarkets\u003c\/li\u003e\n\u003cli\u003eConvenience stores\u003c\/li\u003e\n\u003cli\u003eHotels\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eUniversities\u003c\/li\u003e\n\u003cli\u003eInstitutional kitchens\u003c\/li\u003e\n\u003cli\u003eCorporate cafeterias\u003c\/li\u003e\n\u003cli\u003eCatering operations\u003c\/li\u003e\n\u003cli\u003eCommercial food-storage facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat is Turbo Air part number G8R4500102?\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eTurbo Air G8R4500102\u003c\/strong\u003e is an OEM evaporator coil used in compatible Turbo Air commercial refrigeration equipment, including M3F47 and M3R72 family applications.\u003c\/p\u003e\n\n\u003ch3\u003eWhat models fit the Turbo Air G8R4500102 evaporator coil?\u003c\/h3\u003e\n\n\u003cp\u003eVerified compatible model references include \u003cstrong\u003eM3F726, M3R723, and M3R726\u003c\/strong\u003e. Always verify the complete model and serial number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eDoes G8R4500102 fit Turbo Air M3F47 equipment?\u003c\/h3\u003e\n\n\u003cp\u003eG8R4500102 is identified for compatible Turbo Air M3F47-family applications. Verify the exact model, serial number, original coil, dimensions, and connections before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eDoes G8R4500102 fit Turbo Air M3R72 equipment?\u003c\/h3\u003e\n\n\u003cp\u003eG8R4500102 is identified for compatible Turbo Air M3R72-family applications, including the supplied M3R723 and M3R726 model references. Verify the complete equipment identification before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhat are the dimensions of Turbo Air G8R4500102?\u003c\/h3\u003e\n\n\u003cp\u003eThe evaporator coil has overall dimensions of approximately \u003cstrong\u003e4-1\/4\" x 8-5\/8\" x 33-1\/2\"\u003c\/strong\u003e. The finned section measures approximately \u003cstrong\u003e4-1\/4\" x 7\" x 29-1\/2\"\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat does the evaporator coil do?\u003c\/h3\u003e\n\n\u003cp\u003eThe evaporator coil absorbs heat from the refrigerated cabinet as refrigerant moves through the coil. Airflow across the coil transfers cabinet heat into the refrigeration circuit so the equipment can maintain its intended temperature.\u003c\/p\u003e\n\n\u003ch3\u003eCan a leaking evaporator coil cause a Turbo Air freezer to run warm?\u003c\/h3\u003e\n\n\u003cp\u003eYes. A refrigerant leak at the evaporator can reduce refrigeration capacity and contribute to elevated cabinet temperatures. However, other refrigeration and airflow problems can cause similar symptoms, so the system should be diagnosed before replacing the coil.\u003c\/p\u003e\n\n\u003ch3\u003eDoes frost on the Turbo Air evaporator mean the coil is bad?\u003c\/h3\u003e\n\n\u003cp\u003eNo. Frost can result from defrost problems, airflow restrictions, fan problems, door sealing issues, controls, or other refrigeration conditions. Frost alone does not confirm evaporator coil failure.\u003c\/p\u003e\n\n\u003ch3\u003eWhy is only part of my evaporator coil frosting?\u003c\/h3\u003e\n\n\u003cp\u003eA partial frost pattern can be associated with refrigerant-charge problems, restrictions, refrigerant-feed conditions, airflow, or other refrigeration-system issues. Qualified diagnosis using system measurements is recommended.\u003c\/p\u003e\n\n\u003ch3\u003eShould the evaporator fans be inspected when replacing the coil?\u003c\/h3\u003e\n\n\u003cp\u003eYes. Fan motors, fan blades, airflow passages, and shrouds should be inspected because adequate airflow across the evaporator is essential for proper heat transfer.\u003c\/p\u003e\n\n\u003ch3\u003eShould the defrost system be inspected?\u003c\/h3\u003e\n\n\u003cp\u003eYes. If the original complaint involves heavy frost or ice accumulation, applicable defrost controls, sensors, heaters, drainage components, and fan operation should be evaluated before determining that the coil requires replacement.\u003c\/p\u003e\n\n\u003ch3\u003eDoes replacing G8R4500102 require sealed-system refrigeration work?\u003c\/h3\u003e\n\n\u003cp\u003eYes. The evaporator coil is part of the sealed refrigeration circuit. Replacement should be performed by qualified commercial refrigeration personnel using proper refrigerant recovery, leak-testing, evacuation, charging, and system-verification procedures.\u003c\/p\u003e\n\n\u003ch3\u003eHow do I confirm Turbo Air G8R4500102 is the correct evaporator coil?\u003c\/h3\u003e\n\n\u003cp\u003eVerify \u003cstrong\u003eOEM part number G8R4500102\u003c\/strong\u003e, the complete Turbo Air model and serial number, overall dimensions, finned dimensions, refrigerant connections, mounting points, tubing configuration, and the original evaporator coil before ordering.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Buy From Parts Direct Online?\u003c\/h2\u003e\n\n\u003cp\u003eParts Direct Online supplies OEM commercial refrigeration and commercial cooking replacement parts for service technicians, contractors, restaurants, supermarkets, convenience stores, schools, hospitals, institutional kitchens, and foodservice facilities throughout the United States.\u003c\/p\u003e\n\n\u003cp\u003eOur focus is accurate OEM part identification, commercial equipment fitment support, and helping professional buyers locate the correct replacement component for commercial refrigeration repairs.\u003c\/p\u003e","brand":"Turbo Air","offers":[{"title":"Default Title","offer_id":48408411635935,"sku":"126-378","price":815.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/3047\/0623\/files\/turbo-air-m3f47-2-evaporator-coil-oem-replacement-part-partsdirectonline-1411141.webp?v=1769967023","url":"https:\/\/partsdirectonline.com\/products\/turbo-air-g8r4500102-evaporator-coil","provider":"PartsDirectonline","version":"1.0","type":"link"}