{"product_id":"continental-cm6-0907-evaporator-drain-pan","title":"Continental CM6-0907 OEM Evaporator Drain Pan","description":"\u003ch2\u003eContinental CM6-0907 OEM Evaporator Drain Pan – New Style\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eContinental Refrigeration CM6-0907 Evaporator Drain Pan\u003c\/strong\u003e is a genuine OEM condensate-management component designed for compatible Continental commercial refrigeration equipment. Continental identifies CM6-0907 as the \u003cstrong\u003eNew Style evaporator drain pan\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe pan collects water produced around the evaporator section during normal refrigeration operation and defrost conditions, then directs that condensate toward the equipment's drainage system. Proper drainage is important because standing or overflowing water can contribute to moisture problems, ice buildup, corrosion, cabinet damage, and service interruptions.\u003c\/p\u003e\n\n\u003cp\u003eWhen inspection confirms that the original pan is cracked, corroded, leaking, distorted, or no longer directing condensate correctly, replacing it with the correct \u003cstrong\u003eContinental OEM CM6-0907\u003c\/strong\u003e helps restore the original evaporator drainage configuration intended for compatible equipment.\u003c\/p\u003e\n\n\u003ch2\u003eOEM Part Details\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Continental Refrigeration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e CM6-0907\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CM6-0907\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Evaporator Drain Pan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStyle:\u003c\/strong\u003e New Style\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Commercial Refrigeration Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem:\u003c\/strong\u003e Evaporator Drainage \/ Condensate Management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Condensate Collection \u0026amp; Drain Routing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat the Continental CM6-0907 Drain Pan Does\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eCM6-0907 evaporator drain pan\u003c\/strong\u003e sits beneath or within the applicable evaporator section and collects moisture generated as the refrigeration system operates. The pan channels that water toward the intended drain connection so it can leave the evaporator area properly.\u003c\/p\u003e\n\n\u003cp\u003eProper drain-pan operation helps support:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eControlled condensate collection\u003c\/li\u003e\n\u003cli\u003eProper drainage from the evaporator section\u003c\/li\u003e\n\u003cli\u003eReduced standing water inside the cabinet\u003c\/li\u003e\n\u003cli\u003eReduced water leakage\u003c\/li\u003e\n\u003cli\u003eReduced ice accumulation caused by trapped water\u003c\/li\u003e\n\u003cli\u003eReduced corrosion around refrigeration components\u003c\/li\u003e\n\u003cli\u003eCleaner commercial refrigeration operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCommon Signs of a Damaged Evaporator Drain Pan\u003c\/h2\u003e\n\n\u003cp\u003eQualified commercial refrigeration technicians may inspect Continental CM6-0907 when troubleshooting conditions such as:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eWater leaking from the evaporator area\u003c\/li\u003e\n\u003cli\u003eStanding water inside the cabinet\u003c\/li\u003e\n\u003cli\u003eWater collecting beneath the refrigeration unit\u003c\/li\u003e\n\u003cli\u003eVisible crack in the drain pan\u003c\/li\u003e\n\u003cli\u003eCorrosion or physical deterioration\u003c\/li\u003e\n\u003cli\u003ePan is bent or distorted\u003c\/li\u003e\n\u003cli\u003eDrain outlet no longer aligns correctly\u003c\/li\u003e\n\u003cli\u003eMounting points are damaged\u003c\/li\u003e\n\u003cli\u003eWater spills even though the drain line is clear\u003c\/li\u003e\n\u003cli\u003eRepeated ice buildup around the evaporator drain area\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThese symptoms do not automatically confirm drain-pan failure. A blocked drain line, frozen drain, incorrect equipment leveling, excessive condensate production, defrost problems, or door-gasket leakage can produce similar symptoms. Inspect the complete drainage system before replacing the pan.\u003c\/p\u003e\n\n\u003ch2\u003eDiagnosing Water Leaks Around the Evaporator\u003c\/h2\u003e\n\n\u003cp\u003eA refrigeration cabinet leaking water should be evaluated systematically. Before replacing CM6-0907, technicians should determine whether the pan itself is leaking or whether condensate is failing to reach or leave the pan correctly.\u003c\/p\u003e\n\n\u003cp\u003eInspect:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eDrain pan for cracks or corrosion\u003c\/li\u003e\n\u003cli\u003eDrain outlet position\u003c\/li\u003e\n\u003cli\u003eDrain tubing and fittings\u003c\/li\u003e\n\u003cli\u003eEvaporator drain opening\u003c\/li\u003e\n\u003cli\u003eIce or debris restrictions\u003c\/li\u003e\n\u003cli\u003eEquipment leveling\u003c\/li\u003e\n\u003cli\u003eDefrost operation\u003c\/li\u003e\n\u003cli\u003eDoor gasket condition\u003c\/li\u003e\n\u003cli\u003eWarm-air infiltration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCheck the Drain Outlet \u0026amp; Drain Path\u003c\/h2\u003e\n\n\u003cp\u003eThe pan's outlet must align with the original equipment drainage route. Even a sound replacement pan will not manage condensate correctly if the outlet is misaligned, blocked, or connected improperly.\u003c\/p\u003e\n\n\u003cp\u003eBefore installation, compare:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eOutlet location\u003c\/li\u003e\n\u003cli\u003eOutlet orientation\u003c\/li\u003e\n\u003cli\u003eDrain fitting arrangement\u003c\/li\u003e\n\u003cli\u003eDrain tubing route\u003c\/li\u003e\n\u003cli\u003eMounting position\u003c\/li\u003e\n\u003cli\u003eClearance around surrounding components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInspect for Ice Buildup\u003c\/h2\u003e\n\n\u003cp\u003eIce around the evaporator drainage area can prevent water from reaching or leaving the pan correctly. If ice has damaged the original pan, determine why the evaporator area is icing before installing the replacement.\u003c\/p\u003e\n\n\u003cp\u003ePossible causes include:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eDefrost-system problems\u003c\/li\u003e\n\u003cli\u003eFailed defrost heater\u003c\/li\u003e\n\u003cli\u003eDefrost-termination problems\u003c\/li\u003e\n\u003cli\u003eEvaporator fan problems\u003c\/li\u003e\n\u003cli\u003eDoor gasket leakage\u003c\/li\u003e\n\u003cli\u003eWarm-air infiltration\u003c\/li\u003e\n\u003cli\u003eBlocked drain system\u003c\/li\u003e\n\u003cli\u003eTemperature-control problems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDoor Gaskets \u0026amp; Excess Condensate\u003c\/h2\u003e\n\n\u003cp\u003eA leaking refrigeration door gasket can allow warm, humid air into the cabinet and increase moisture production around the evaporator. Excess condensate may overwhelm a drainage system that would otherwise operate normally.\u003c\/p\u003e\n\n\u003cp\u003eIf condensate volume seems unusually high, inspect:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eDoor gasket condition\u003c\/li\u003e\n\u003cli\u003eDoor alignment\u003c\/li\u003e\n\u003cli\u003eHinges and closing hardware\u003c\/li\u003e\n\u003cli\u003eVisible air gaps\u003c\/li\u003e\n\u003cli\u003eFrequency of door openings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnician Checks Before Ordering\u003c\/h2\u003e\n\n\u003cp\u003eBefore ordering Continental CM6-0907, verify:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eOEM part number \u003cstrong\u003eCM6-0907\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eComplete Continental equipment model\u003c\/li\u003e\n\u003cli\u003eEquipment serial number\u003c\/li\u003e\n\u003cli\u003eOriginal drain-pan markings\u003c\/li\u003e\n\u003cli\u003ePan overall dimensions\u003c\/li\u003e\n\u003cli\u003eDrain outlet location\u003c\/li\u003e\n\u003cli\u003eDrain fitting arrangement\u003c\/li\u003e\n\u003cli\u003eMounting-point locations\u003c\/li\u003e\n\u003cli\u003ePan orientation\u003c\/li\u003e\n\u003cli\u003eRelationship to the evaporator assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eDo not order a drain pan by general shape alone.\u003c\/strong\u003e Similar-looking pans can use different lengths, widths, outlet locations, mounting points, depths, and equipment applications.\u003c\/p\u003e\n\n\u003ch2\u003eNo Verified Public Model List\u003c\/h2\u003e\n\n\u003cp\u003eA reliable public model-fitment list is not currently provided for CM6-0907 in the OEM parts source used for this listing. For that reason, the strongest fitment method is to verify the \u003cstrong\u003eCM6-0907 OEM number\u003c\/strong\u003e against the equipment model, serial number, original pan, and Continental service documentation before ordering.\u003c\/p\u003e\n\n\u003ch2\u003eCommercial Refrigeration Applications\u003c\/h2\u003e\n\n\u003cp\u003eContinental commercial refrigeration equipment is used in demanding foodservice environments including:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eHotels\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eUniversities\u003c\/li\u003e\n\u003cli\u003eInstitutional kitchens\u003c\/li\u003e\n\u003cli\u003eSupermarkets\u003c\/li\u003e\n\u003cli\u003eConvenience stores\u003c\/li\u003e\n\u003cli\u003eFoodservice facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Service Notes\u003c\/h2\u003e\n\n\u003cp\u003eDisconnect electrical power where required before servicing commercial refrigeration equipment.\u003c\/p\u003e\n\n\u003cp\u003eBefore removing the original pan, document:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003ePan orientation\u003c\/li\u003e\n\u003cli\u003eMounting points\u003c\/li\u003e\n\u003cli\u003eDrain outlet position\u003c\/li\u003e\n\u003cli\u003eDrain connection\u003c\/li\u003e\n\u003cli\u003eRelationship to the evaporator coil\u003c\/li\u003e\n\u003cli\u003eClearance from surrounding components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCompare the replacement Continental CM6-0907 with the original pan before installation.\u003c\/p\u003e\n\n\u003cp\u003eAfter installation, verify:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe pan sits securely in the intended position\u003c\/li\u003e\n\u003cli\u003eCondensate enters the pan correctly\u003c\/li\u003e\n\u003cli\u003eThe drain outlet aligns with the original drain route\u003c\/li\u003e\n\u003cli\u003eWater flows freely through the drain system\u003c\/li\u003e\n\u003cli\u003eNo leaks are present\u003c\/li\u003e\n\u003cli\u003eNo water spills over the pan edges\u003c\/li\u003e\n\u003cli\u003eThe evaporator area remains properly drained during operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy Correct Continental OEM Identification Matters\u003c\/h2\u003e\n\n\u003cp\u003eCommercial refrigeration drain pans can appear similar while using different dimensions, drain-outlet locations, mounting points, and equipment applications.\u003c\/p\u003e\n\n\u003cp\u003eUsing \u003cstrong\u003eContinental Refrigeration OEM part number CM6-0907\u003c\/strong\u003e provides the clearest replacement reference when comparing the new pan with the original component.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat is Continental CM6-0907?\u003c\/h3\u003e\n\u003cp\u003eContinental CM6-0907 is a genuine OEM evaporator drain pan used in compatible Continental commercial refrigeration equipment.\u003c\/p\u003e\n\n\u003ch3\u003eIs CM6-0907 a Genuine OEM Continental part?\u003c\/h3\u003e\n\u003cp\u003eYes. Current Continental parts listings identify CM6-0907 as a genuine OEM evaporator drain pan.\u003c\/p\u003e\n\n\u003ch3\u003eIs CM6-0907 the New Style drain pan?\u003c\/h3\u003e\n\u003cp\u003eYes. Current OEM parts listings describe CM6-0907 as the \u003cstrong\u003eNew Style\u003c\/strong\u003e evaporator drain pan.\u003c\/p\u003e\n\n\u003ch3\u003eWhat does an evaporator drain pan do?\u003c\/h3\u003e\n\u003cp\u003eThe pan collects condensate from the evaporator area and directs the water toward the refrigeration equipment's drainage system.\u003c\/p\u003e\n\n\u003ch3\u003eCan a cracked drain pan cause water leaks?\u003c\/h3\u003e\n\u003cp\u003eYes. A cracked, corroded, or distorted pan can allow condensate to leak into the cabinet or onto the surrounding floor.\u003c\/p\u003e\n\n\u003ch3\u003eCan a blocked drain make it look like the pan is bad?\u003c\/h3\u003e\n\u003cp\u003eYes. A blocked or frozen drain can cause water to back up and overflow even when the pan itself is intact.\u003c\/p\u003e\n\n\u003ch3\u003eCan evaporator icing damage the drain pan?\u003c\/h3\u003e\n\u003cp\u003eYes. Repeated ice accumulation can distort or damage the pan and should be diagnosed before installing a replacement.\u003c\/p\u003e\n\n\u003ch3\u003eShould door gaskets be inspected when there is excessive condensate?\u003c\/h3\u003e\n\u003cp\u003eYes. Warm-air infiltration through a damaged door gasket can increase moisture and condensate production.\u003c\/p\u003e\n\n\u003ch3\u003eDoes Continental publish a model list for CM6-0907?\u003c\/h3\u003e\n\u003cp\u003eA reliable model-fitment list was not available from the OEM parts source checked for this listing. Verify the model, serial number, original part, and OEM number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eCan I replace CM6-0907 with another long drain pan that looks similar?\u003c\/h3\u003e\n\u003cp\u003eNo. Verify OEM number CM6-0907, pan dimensions, outlet location, mounting points, equipment model, and serial number.\u003c\/p\u003e\n\n\u003ch3\u003eHow do I confirm Continental CM6-0907 is correct?\u003c\/h3\u003e\n\u003cp\u003eVerify OEM part number \u003cstrong\u003eCM6-0907\u003c\/strong\u003e, the complete Continental model and serial number, original drain-pan markings, dimensions, drain outlet, mounting arrangement, and equipment configuration before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eIs professional installation recommended?\u003c\/h3\u003e\n\u003cp\u003eQualified commercial refrigeration personnel can verify pan fitment, drainage, evaporator condition, defrost operation, and overall condensate management during replacement.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Buy From Parts Direct Online?\u003c\/h2\u003e\n\n\u003cp\u003eParts Direct Online supplies OEM commercial refrigeration drain pans, evaporator components, fan motors, controls, gaskets, heaters, defrost parts, and related replacement components for service technicians, contractors, restaurants, supermarkets, hotels, institutional kitchens, and commercial foodservice facilities throughout the United States.\u003c\/p\u003e","brand":"Continental Refrigerator","offers":[{"title":"Default Title","offer_id":47557148639455,"sku":"CM6-0907","price":335.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/3047\/0623\/files\/continental-evaporator-drain-pan-5-14-x-51-14-x-58-oem-compatible-universal-fit-partsdirectonline-4713514.webp?v=1765852685","url":"https:\/\/partsdirectonline.com\/products\/continental-cm6-0907-evaporator-drain-pan","provider":"PartsDirectonline","version":"1.0","type":"link"}