{"product_id":"continental-50207-condensate-drain-pan-heater-115v-160w","title":"Continental 50207 OEM Condensate Drain Pan with Heater – 115V 160W","description":"\u003ch2\u003eContinental 50207 OEM Condensate Drain Pan with Heater – 115V 160W\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eContinental Refrigeration 50207 Condensate Drain Pan\u003c\/strong\u003e is a genuine OEM commercial refrigeration drain-pan assembly equipped with a condensate evaporator heater. Rated for \u003cstrong\u003e115V and 160W\u003c\/strong\u003e and supplied with an \u003cstrong\u003e8-foot cord\u003c\/strong\u003e, this assembly is designed to collect refrigeration condensate and provide controlled heat that helps evaporate collected water during normal equipment operation.\u003c\/p\u003e\n\n\u003cp\u003eProper condensate management is important in commercial refrigeration because water that does not drain or evaporate correctly can contribute to overflow, standing water, floor moisture, corrosion, electrical concerns, and service interruptions.\u003c\/p\u003e\n\n\u003cp\u003eWhen qualified diagnosis confirms that the original drain pan or condensate evaporator assembly requires replacement, using the correct \u003cstrong\u003eContinental OEM 50207\u003c\/strong\u003e helps restore the original condensate-management configuration intended for compatible Continental refrigeration equipment.\u003c\/p\u003e\n\n\u003ch2\u003eOEM Part Details \u0026amp; Specifications\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Continental Refrigeration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Part Number:\u003c\/strong\u003e 50207\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e 50207\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Condensate Drain Pan with Evaporator Heater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 115V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWattage:\u003c\/strong\u003e 160W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCord Length:\u003c\/strong\u003e 8 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Commercial Refrigeration Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem:\u003c\/strong\u003e Condensate Drainage \/ Evaporation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Condensate Collection \u0026amp; Water Evaporation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat the Continental 50207 Drain Pan Does\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eContinental 50207 condensate pan\u003c\/strong\u003e collects water produced by the refrigeration system and uses its integrated heating function to support evaporation of that condensate. This helps reduce the need for water to remain standing in the pan or overflow into the equipment area.\u003c\/p\u003e\n\n\u003cp\u003eProper condensate-pan operation helps support:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eControlled collection of refrigeration condensate\u003c\/li\u003e\n\u003cli\u003eEvaporation of collected water\u003c\/li\u003e\n\u003cli\u003eReduced standing water\u003c\/li\u003e\n\u003cli\u003eReduced risk of drain-pan overflow\u003c\/li\u003e\n\u003cli\u003eCleaner equipment operation\u003c\/li\u003e\n\u003cli\u003eReduced floor moisture around the unit\u003c\/li\u003e\n\u003cli\u003eDependable commercial refrigeration service\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e115V, 160W Condensate Evaporator Heater\u003c\/h2\u003e\n\n\u003cp\u003eThe Continental 50207 is identified with a \u003cstrong\u003e115V, 160W condensate evaporator heater\u003c\/strong\u003e. Both voltage and wattage are important replacement specifications and should match the original equipment configuration.\u003c\/p\u003e\n\n\u003cp\u003eDo not substitute another heated drain pan based solely on physical appearance. Similar pans may use different voltages, heater wattages, electrical connections, cord lengths, dimensions, mounting points, or equipment applications.\u003c\/p\u003e\n\n\u003ch2\u003e8-Foot Power Cord\u003c\/h2\u003e\n\n\u003cp\u003eThis assembly is supplied with an approximately \u003cstrong\u003e8-foot electrical cord\u003c\/strong\u003e. Cord length and routing should be compared with the original installation so the replacement can be connected without stretching, pinching, or creating interference with moving or heated components.\u003c\/p\u003e\n\n\u003ch2\u003eCommon Signs of a Condensate Drain Pan or Heater Problem\u003c\/h2\u003e\n\n\u003cp\u003eQualified commercial refrigeration technicians may inspect the Continental 50207 when troubleshooting conditions such as:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eStanding water remains in the condensate pan\u003c\/li\u003e\n\u003cli\u003eDrain pan repeatedly overflows\u003c\/li\u003e\n\u003cli\u003eWater collects beneath the refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eCondensate does not evaporate during normal operation\u003c\/li\u003e\n\u003cli\u003eHeater does not warm when energized\u003c\/li\u003e\n\u003cli\u003eHeater operates intermittently\u003c\/li\u003e\n\u003cli\u003eElectrical cord or terminals show damage\u003c\/li\u003e\n\u003cli\u003eDrain pan is corroded, cracked, or physically damaged\u003c\/li\u003e\n\u003cli\u003eWater leaks from the pan area\u003c\/li\u003e\n\u003cli\u003eMoisture or corrosion develops around nearby equipment components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThese symptoms do not automatically confirm that the 50207 assembly itself has failed. Excessive condensate production, drainage restrictions, door-gasket leakage, high ambient humidity, defrost problems, wiring issues, or other refrigeration conditions can create similar symptoms. Diagnose the complete condensate system before replacing the assembly.\u003c\/p\u003e\n\n\u003ch2\u003eDiagnosing Standing Water in the Drain Pan\u003c\/h2\u003e\n\n\u003cp\u003eIf water remains in the pan, technicians should determine whether the problem is caused by the heating element, excessive condensate production, drainage conditions, or an electrical supply problem.\u003c\/p\u003e\n\n\u003cp\u003eDepending on the equipment configuration, inspect:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e115V electrical supply to the heater\u003c\/li\u003e\n\u003cli\u003eHeater operation\u003c\/li\u003e\n\u003cli\u003eElectrical cord and connectors\u003c\/li\u003e\n\u003cli\u003eDrain-pan condition\u003c\/li\u003e\n\u003cli\u003eCondensate volume\u003c\/li\u003e\n\u003cli\u003eDrainage path\u003c\/li\u003e\n\u003cli\u003eDoor sealing\u003c\/li\u003e\n\u003cli\u003eDefrost operation\u003c\/li\u003e\n\u003cli\u003eAmbient humidity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDiagnosing a Drain Pan That Overflows\u003c\/h2\u003e\n\n\u003cp\u003eAn overflowing condensate pan does not automatically mean the pan is defective. Overflow may occur if more water enters the pan than the heater can evaporate or if another refrigeration-system condition produces excessive condensate.\u003c\/p\u003e\n\n\u003cp\u003ePossible areas to inspect include:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCondensate evaporator heater\u003c\/li\u003e\n\u003cli\u003eWater drainage path\u003c\/li\u003e\n\u003cli\u003eDoor gasket leakage\u003c\/li\u003e\n\u003cli\u003eWarm-air infiltration\u003c\/li\u003e\n\u003cli\u003eDefrost-system operation\u003c\/li\u003e\n\u003cli\u003eEquipment leveling\u003c\/li\u003e\n\u003cli\u003eAmbient temperature and humidity\u003c\/li\u003e\n\u003cli\u003ePan positioning\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInspect the Heater Circuit\u003c\/h2\u003e\n\n\u003cp\u003eIf the pan fills but the collected water is not evaporating, qualified technicians should verify that the heater receives the correct electrical supply and that the electrical circuit is intact.\u003c\/p\u003e\n\n\u003cp\u003eInspect for:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eCorrect 115V supply\u003c\/li\u003e\n\u003cli\u003eDamaged cord\u003c\/li\u003e\n\u003cli\u003eLoose terminals\u003c\/li\u003e\n\u003cli\u003eBurned connectors\u003c\/li\u003e\n\u003cli\u003eBroken conductors\u003c\/li\u003e\n\u003cli\u003eCorrosion\u003c\/li\u003e\n\u003cli\u003eHeat-damaged insulation\u003c\/li\u003e\n\u003cli\u003eEvidence of electrical arcing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eAny wiring or connection problem should be corrected before the replacement drain-pan assembly is energized.\u003c\/p\u003e\n\n\u003ch2\u003eInspect the Drainage System\u003c\/h2\u003e\n\n\u003cp\u003eThe condensate pan is only one part of the equipment's moisture-management system. A blocked or misdirected drain path can create water problems even when the pan and heater are operating correctly.\u003c\/p\u003e\n\n\u003cp\u003eCheck applicable:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eDrain tubes\u003c\/li\u003e\n\u003cli\u003eDrain fittings\u003c\/li\u003e\n\u003cli\u003eEvaporator drain\u003c\/li\u003e\n\u003cli\u003eDefrost drainage\u003c\/li\u003e\n\u003cli\u003ePan position\u003c\/li\u003e\n\u003cli\u003eEquipment leveling\u003c\/li\u003e\n\u003cli\u003eDebris or scale restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eDoor Gaskets \u0026amp; Excess Condensate\u003c\/h2\u003e\n\n\u003cp\u003eA leaking refrigeration door gasket can allow warm, humid air into the cabinet and increase the amount of moisture the refrigeration system must remove.\u003c\/p\u003e\n\n\u003cp\u003eIf condensate volume appears excessive, inspect the door system for:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eTorn or flattened gaskets\u003c\/li\u003e\n\u003cli\u003eDoor misalignment\u003c\/li\u003e\n\u003cli\u003eLoose hinges\u003c\/li\u003e\n\u003cli\u003eIncomplete door closure\u003c\/li\u003e\n\u003cli\u003eVisible air gaps\u003c\/li\u003e\n\u003cli\u003eRepeated door openings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCorrecting air infiltration can reduce unnecessary condensate production and refrigeration load.\u003c\/p\u003e\n\n\u003ch2\u003eTechnician Checks Before Ordering\u003c\/h2\u003e\n\n\u003cp\u003eBefore ordering Continental 50207, verify:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eOEM part number \u003cstrong\u003e50207\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eComplete Continental equipment model\u003c\/li\u003e\n\u003cli\u003eEquipment serial number\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e115V\u003c\/strong\u003e electrical requirement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e160W\u003c\/strong\u003e heater requirement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-foot cord\u003c\/strong\u003e configuration\u003c\/li\u003e\n\u003cli\u003eOriginal drain-pan shape and dimensions\u003c\/li\u003e\n\u003cli\u003eMounting arrangement\u003c\/li\u003e\n\u003cli\u003eElectrical connector \/ cord routing\u003c\/li\u003e\n\u003cli\u003eCondensate inlet location\u003c\/li\u003e\n\u003cli\u003eAvailable clearance around the pan\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eDo not order by pan shape alone.\u003c\/strong\u003e Heated drain pans can have similar appearances while using different electrical ratings, dimensions, cord lengths, mounting points, and equipment applications.\u003c\/p\u003e\n\n\u003ch2\u003eCommercial Refrigeration Applications\u003c\/h2\u003e\n\n\u003cp\u003eContinental commercial refrigeration equipment is used in demanding foodservice environments including:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eHotels\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eUniversities\u003c\/li\u003e\n\u003cli\u003eInstitutional kitchens\u003c\/li\u003e\n\u003cli\u003eSupermarkets\u003c\/li\u003e\n\u003cli\u003eConvenience stores\u003c\/li\u003e\n\u003cli\u003eFoodservice facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Electrical Safety Notes\u003c\/h2\u003e\n\n\u003cp\u003eDisconnect electrical power before servicing commercial refrigeration condensate or heater components.\u003c\/p\u003e\n\n\u003cp\u003eBefore removing the original assembly, document:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eDrain-pan orientation\u003c\/li\u003e\n\u003cli\u003eMounting position\u003c\/li\u003e\n\u003cli\u003eElectrical cord routing\u003c\/li\u003e\n\u003cli\u003eCondensate entry point\u003c\/li\u003e\n\u003cli\u003eRelationship to surrounding refrigeration components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCompare the replacement Continental 50207 with the original pan before installation.\u003c\/p\u003e\n\n\u003cp\u003eAfter installation, verify:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe pan sits securely in the intended position\u003c\/li\u003e\n\u003cli\u003eCondensate enters the pan correctly\u003c\/li\u003e\n\u003cli\u003eThe electrical cord is routed safely\u003c\/li\u003e\n\u003cli\u003eNo wiring contacts sharp or excessively hot surfaces\u003c\/li\u003e\n\u003cli\u003eThe heater operates correctly\u003c\/li\u003e\n\u003cli\u003eNo water leaks are present\u003c\/li\u003e\n\u003cli\u003eCondensate is managed normally during equipment operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCommercial refrigeration heater and condensate components should be diagnosed and installed by qualified refrigeration service personnel.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Correct Continental OEM Identification Matters\u003c\/h2\u003e\n\n\u003cp\u003eCondensate drain pans with evaporator heaters can appear similar while using different voltages, wattages, dimensions, cord lengths, mounting configurations, and equipment applications.\u003c\/p\u003e\n\n\u003cp\u003eUsing \u003cstrong\u003eContinental Refrigeration OEM part number 50207\u003c\/strong\u003e together with the verified \u003cstrong\u003e115V, 160W, 8-foot cord\u003c\/strong\u003e specifications provides a much stronger replacement reference than selecting by appearance alone.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat is Continental 50207?\u003c\/h3\u003e\n\u003cp\u003eContinental 50207 is a genuine OEM condensate drain pan with condensate evaporator heater used in compatible Continental commercial refrigeration equipment.\u003c\/p\u003e\n\n\u003ch3\u003eWhat voltage is Continental 50207?\u003c\/h3\u003e\n\u003cp\u003eThe assembly is identified for \u003cstrong\u003e115V\u003c\/strong\u003e operation.\u003c\/p\u003e\n\n\u003ch3\u003eWhat wattage is the heater?\u003c\/h3\u003e\n\u003cp\u003eThe integrated condensate evaporator heater is rated at \u003cstrong\u003e160W\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eHow long is the power cord?\u003c\/h3\u003e\n\u003cp\u003ePublished parts data identifies an \u003cstrong\u003e8-foot cord\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat does the condensate evaporator do?\u003c\/h3\u003e\n\u003cp\u003eThe heater provides controlled heat to the drain pan to help evaporate collected refrigeration condensate.\u003c\/p\u003e\n\n\u003ch3\u003eCan a bad drain-pan heater cause water to overflow?\u003c\/h3\u003e\n\u003cp\u003eYes. If the heater does not evaporate condensate properly, water may accumulate. Excessive condensate or drainage problems can produce the same symptom.\u003c\/p\u003e\n\n\u003ch3\u003eCan a leaking door gasket cause extra condensate?\u003c\/h3\u003e\n\u003cp\u003eYes. Warm, humid air entering through a poor door seal can increase moisture accumulation inside refrigeration equipment.\u003c\/p\u003e\n\n\u003ch3\u003eShould the drain system be inspected before replacing the pan?\u003c\/h3\u003e\n\u003cp\u003eYes. Verify drainage, pan positioning, condensate flow, and heater operation before concluding that the complete pan assembly requires replacement.\u003c\/p\u003e\n\n\u003ch3\u003eDoes Continental 50207 have a verified model-fitment list?\u003c\/h3\u003e\n\u003cp\u003eA reliable public model list is not currently provided by the parts source used for this listing. Verify the complete Continental model and serial number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eCan I replace 50207 with another 115V heated drain pan?\u003c\/h3\u003e\n\u003cp\u003eNo. Verify OEM part number \u003cstrong\u003e50207\u003c\/strong\u003e, wattage, dimensions, cord length, mounting arrangement, model, and serial number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eHow do I confirm Continental 50207 is correct?\u003c\/h3\u003e\n\u003cp\u003eVerify OEM part number \u003cstrong\u003e50207\u003c\/strong\u003e, the complete Continental model and serial number, 115V rating, 160W heater, 8-foot cord, pan configuration, and mounting arrangement before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eIs professional installation recommended?\u003c\/h3\u003e\n\u003cp\u003eYes. Commercial refrigeration electrical and condensate-management components should be diagnosed and installed by qualified refrigeration service personnel.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Buy From Parts Direct Online?\u003c\/h2\u003e\n\n\u003cp\u003eParts Direct Online supplies OEM commercial refrigeration drain pans, evaporator heaters, fan motors, controls, gaskets, defrost parts, and related replacement components for service technicians, contractors, restaurants, supermarkets, hotels, institutional kitchens, and foodservice facilities throughout the United States.\u003c\/p\u003e","brand":"Continental Refrigerator","offers":[{"title":"Default Title","offer_id":47557160468703,"sku":"50207","price":282.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/3047\/0623\/files\/continental-condensate-drain-pan-with-heater-115v-160w-oem-compatible-partsdirectonline-2804431.jpg?v=1765852748","url":"https:\/\/partsdirectonline.com\/products\/continental-50207-condensate-drain-pan-heater-115v-160w","provider":"PartsDirectonline","version":"1.0","type":"link"}