{"product_id":"14-inch-ccw-fan-blade-27-degree-pitch-4-blade","title":"14\" Commercial Refrigeration Fan Blade – CCW, 27° Pitch, 4 Blade","description":"\u003ch2\u003e14\" Commercial Refrigeration Fan Blade – CCW Rotation, 27° Pitch, 4 Blades\u003c\/h2\u003e\n\n\u003cp\u003eThis \u003cstrong\u003e14-inch commercial refrigeration fan blade\u003c\/strong\u003e is a four-blade replacement designed for compatible refrigeration and cooling-system fan assemblies. The blade is identified by its \u003cstrong\u003ecounterclockwise (CCW) rotation\u003c\/strong\u003e, \u003cstrong\u003e27-degree pitch\u003c\/strong\u003e, and \u003cstrong\u003e4-blade configuration\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eCorrect fan-blade selection is critical to refrigeration airflow. A blade with the wrong diameter, pitch, rotation, hub configuration, or mounting arrangement can produce incorrect airflow, excessive motor load, vibration, poor condenser or evaporator performance, and reduced equipment efficiency.\u003c\/p\u003e\n\n\u003cp\u003eBefore ordering, compare the original fan blade carefully and verify the \u003cstrong\u003e14\" diameter, CCW rotation, 27° pitch, four-blade design, hub configuration, shaft mounting, and intended airflow direction\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Type:\u003c\/strong\u003e Commercial Refrigeration Fan Blade\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlade Diameter:\u003c\/strong\u003e 14\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotation:\u003c\/strong\u003e Counterclockwise (CCW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePitch:\u003c\/strong\u003e 27 Degrees\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Blades:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Commercial Refrigeration \/ Cooling Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Refrigeration Airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat This 14\" Fan Blade Does\u003c\/h2\u003e\n\n\u003cp\u003eThe fan blade mounts to the applicable fan motor and moves air through the refrigeration system. Depending on the equipment configuration, the blade may support condenser airflow, evaporator airflow, or another cooling-air application.\u003c\/p\u003e\n\n\u003cp\u003eProper fan-blade operation helps support:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eConsistent refrigeration airflow\u003c\/li\u003e\n\u003cli\u003eProper heat transfer\u003c\/li\u003e\n\u003cli\u003eNormal condenser or evaporator performance\u003c\/li\u003e\n\u003cli\u003eReduced excessive motor load\u003c\/li\u003e\n\u003cli\u003eStable refrigeration-system operation\u003c\/li\u003e\n\u003cli\u003eConsistent equipment temperatures\u003c\/li\u003e\n\u003cli\u003eDependable commercial refrigeration performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e14-Inch Diameter\u003c\/h2\u003e\n\n\u003cp\u003eThis replacement fan blade is identified as \u003cstrong\u003e14 inches in diameter\u003c\/strong\u003e. Diameter must match the original fan assembly closely enough to provide proper shroud clearance and airflow.\u003c\/p\u003e\n\n\u003cp\u003eA blade that is too large may contact the guard or shroud. A blade that is too small may not provide the airflow required by the equipment.\u003c\/p\u003e\n\n\u003ch2\u003eCounterclockwise Rotation\u003c\/h2\u003e\n\n\u003cp\u003eThis blade is identified for \u003cstrong\u003eCCW rotation\u003c\/strong\u003e. Rotation is a critical replacement characteristic because installing a blade with the wrong rotation can move air in the wrong direction or provide significantly reduced airflow.\u003c\/p\u003e\n\n\u003cp\u003eAlways compare the original blade and confirm how the manufacturer defines rotation. Fan-blade rotation may be specified from a particular viewing side of the motor or blade assembly, so the original equipment configuration should be used as the final reference.\u003c\/p\u003e\n\n\u003ch2\u003e27-Degree Blade Pitch\u003c\/h2\u003e\n\n\u003cp\u003eThe blade is identified with a \u003cstrong\u003e27-degree pitch\u003c\/strong\u003e. Blade pitch influences how much air the fan moves and how much load is placed on the motor.\u003c\/p\u003e\n\n\u003cp\u003eChanging pitch can affect:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eAirflow volume\u003c\/li\u003e\n\u003cli\u003eMotor amperage\u003c\/li\u003e\n\u003cli\u003eMotor temperature\u003c\/li\u003e\n\u003cli\u003eStatic-pressure performance\u003c\/li\u003e\n\u003cli\u003eRefrigeration heat transfer\u003c\/li\u003e\n\u003cli\u003eNoise and vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eDo not substitute a different blade pitch solely because the diameter and number of blades are the same.\u003c\/p\u003e\n\n\u003ch2\u003eFour-Blade Configuration\u003c\/h2\u003e\n\n\u003cp\u003eThis fan uses a \u003cstrong\u003efour-blade design\u003c\/strong\u003e. The number of blades is another important airflow and motor-load characteristic and should match the intended equipment application.\u003c\/p\u003e\n\n\u003ch2\u003eCommon Signs of a Damaged Fan Blade\u003c\/h2\u003e\n\n\u003cp\u003eQualified commercial refrigeration technicians may inspect the fan blade when troubleshooting conditions such as:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eReduced airflow\u003c\/li\u003e\n\u003cli\u003eFan vibration\u003c\/li\u003e\n\u003cli\u003eAbnormal fan noise\u003c\/li\u003e\n\u003cli\u003eBlade rubbing against the shroud or guard\u003c\/li\u003e\n\u003cli\u003eCracked blade\u003c\/li\u003e\n\u003cli\u003eBent blade\u003c\/li\u003e\n\u003cli\u003eLoose blade on the motor shaft\u003c\/li\u003e\n\u003cli\u003eUneven blade tracking\u003c\/li\u003e\n\u003cli\u003eEquipment running warmer than expected\u003c\/li\u003e\n\u003cli\u003eMotor overheating\u003c\/li\u003e\n\u003cli\u003eFan assembly repeatedly going out of balance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThese symptoms do not automatically confirm blade failure. Fan-motor bearings, motor mounting, guards, shrouds, ice buildup, debris, wiring, and refrigeration-system conditions can produce similar symptoms.\u003c\/p\u003e\n\n\u003ch2\u003eInspect the Fan Motor Before Replacing the Blade\u003c\/h2\u003e\n\n\u003cp\u003eA damaged fan blade can sometimes be the result of a motor or mounting problem. Before installing a replacement blade, inspect the fan motor for:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eExcessive shaft play\u003c\/li\u003e\n\u003cli\u003eWorn bearings\u003c\/li\u003e\n\u003cli\u003eBent motor shaft\u003c\/li\u003e\n\u003cli\u003eLoose mounting hardware\u003c\/li\u003e\n\u003cli\u003eExcessive vibration\u003c\/li\u003e\n\u003cli\u003eIncorrect motor rotation\u003c\/li\u003e\n\u003cli\u003eMotor overheating\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eA motor with excessive shaft movement can cause the replacement blade to wobble, contact surrounding components, or fail prematurely.\u003c\/p\u003e\n\n\u003ch2\u003eCheck Shroud \u0026amp; Guard Clearance\u003c\/h2\u003e\n\n\u003cp\u003eAfter installation, the blade must rotate freely without contacting the fan guard, shroud, coil, wiring, or surrounding refrigeration components.\u003c\/p\u003e\n\n\u003cp\u003eVerify:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eBlade is centered correctly\u003c\/li\u003e\n\u003cli\u003eClearance is consistent around the full rotation\u003c\/li\u003e\n\u003cli\u003eNo blade tips are bent\u003c\/li\u003e\n\u003cli\u003eHub is securely mounted\u003c\/li\u003e\n\u003cli\u003eBlade rotates freely by hand with power disconnected\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAirflow Direction Matters\u003c\/h2\u003e\n\n\u003cp\u003eCorrect blade rotation does not by itself guarantee correct airflow. Blade pitch, mounting orientation, motor rotation, and installation side all affect the final direction of air movement.\u003c\/p\u003e\n\n\u003cp\u003eBefore returning the equipment to service, verify that air is moving in the same intended direction as the original installation.\u003c\/p\u003e\n\n\u003ch2\u003eTechnician Checks Before Ordering\u003c\/h2\u003e\n\n\u003cp\u003eBefore ordering this fan blade, verify:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e14\" blade diameter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCCW rotation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e27° blade pitch\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4-blade configuration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eCenter hub design\u003c\/li\u003e\n\u003cli\u003eShaft diameter \/ mounting arrangement\u003c\/li\u003e\n\u003cli\u003eBlade offset\u003c\/li\u003e\n\u003cli\u003eMotor rotation\u003c\/li\u003e\n\u003cli\u003eRequired airflow direction\u003c\/li\u003e\n\u003cli\u003eFan-shroud clearance\u003c\/li\u003e\n\u003cli\u003eOriginal equipment model\u003c\/li\u003e\n\u003cli\u003eOriginal fan-blade markings where available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eDo not order by diameter alone.\u003c\/strong\u003e A 14-inch fan blade with the wrong pitch, rotation, hub, or mounting arrangement may not operate correctly.\u003c\/p\u003e\n\n\u003ch2\u003eCommercial Refrigeration Applications\u003c\/h2\u003e\n\n\u003cp\u003eThis type of fan blade may be used in compatible commercial refrigeration and cooling equipment found in:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eRestaurants\u003c\/li\u003e\n\u003cli\u003eCommercial kitchens\u003c\/li\u003e\n\u003cli\u003eSupermarkets\u003c\/li\u003e\n\u003cli\u003eConvenience stores\u003c\/li\u003e\n\u003cli\u003eWalk-in coolers\u003c\/li\u003e\n\u003cli\u003eWalk-in freezers\u003c\/li\u003e\n\u003cli\u003eReach-in refrigeration\u003c\/li\u003e\n\u003cli\u003eCold-storage equipment\u003c\/li\u003e\n\u003cli\u003eFoodservice facilities\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Service Notes\u003c\/h2\u003e\n\n\u003cp\u003eDisconnect electrical power before servicing any refrigeration fan assembly.\u003c\/p\u003e\n\n\u003cp\u003eBefore removing the original blade, document:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eBlade orientation\u003c\/li\u003e\n\u003cli\u003eHub position\u003c\/li\u003e\n\u003cli\u003eShaft engagement\u003c\/li\u003e\n\u003cli\u003eMotor rotation\u003c\/li\u003e\n\u003cli\u003eAirflow direction\u003c\/li\u003e\n\u003cli\u003eClearance from surrounding components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCompare the replacement blade with the original before installation.\u003c\/p\u003e\n\n\u003cp\u003eAfter installation, verify that the blade rotates freely, runs without excessive vibration, clears the guard and shroud, and moves air in the proper direction.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Exact Fan Blade Specifications Matter\u003c\/h2\u003e\n\n\u003cp\u003eCommercial refrigeration fan blades can look nearly identical while having different diameters, pitches, rotations, blade counts, offsets, and hub configurations.\u003c\/p\u003e\n\n\u003cp\u003eFor this replacement, the important verified characteristics are \u003cstrong\u003e14\" diameter, CCW rotation, 27° pitch, and four blades\u003c\/strong\u003e. The original hub and mounting configuration should also be matched before ordering.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat size is this fan blade?\u003c\/h3\u003e\n\u003cp\u003eThis fan blade is identified as \u003cstrong\u003e14 inches in diameter\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat rotation is this fan blade?\u003c\/h3\u003e\n\u003cp\u003eIt is identified as a \u003cstrong\u003ecounterclockwise (CCW)\u003c\/strong\u003e fan blade. Confirm the original equipment's viewing reference for rotation before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the pitch of this fan blade?\u003c\/h3\u003e\n\u003cp\u003eThe blade is identified with a \u003cstrong\u003e27-degree pitch\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eHow many blades does it have?\u003c\/h3\u003e\n\u003cp\u003eThis fan blade uses a \u003cstrong\u003efour-blade configuration\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCan I replace another 14-inch fan blade with this one?\u003c\/h3\u003e\n\u003cp\u003eNot based on diameter alone. Rotation, pitch, number of blades, hub design, shaft mounting, offset, and airflow direction must also be compatible.\u003c\/p\u003e\n\n\u003ch3\u003eCan the wrong fan blade make a motor overheat?\u003c\/h3\u003e\n\u003cp\u003eYes. Incorrect pitch, diameter, blade count, or mechanical installation can increase motor load and contribute to overheating.\u003c\/p\u003e\n\n\u003ch3\u003eCan a bent blade cause vibration?\u003c\/h3\u003e\n\u003cp\u003eYes. A bent, cracked, or unbalanced fan blade can produce vibration and place additional stress on the motor bearings.\u003c\/p\u003e\n\n\u003ch3\u003eShould I inspect the motor when replacing the blade?\u003c\/h3\u003e\n\u003cp\u003eYes. Check shaft play, motor bearings, mounting, rotation, and condition before installing the replacement blade.\u003c\/p\u003e\n\n\u003ch3\u003eHow do I confirm this is the correct fan blade?\u003c\/h3\u003e\n\u003cp\u003eVerify the \u003cstrong\u003e14\" diameter, CCW rotation, 27° pitch, four-blade configuration\u003c\/strong\u003e, hub design, shaft mounting, motor rotation, and required airflow direction against the original blade.\u003c\/p\u003e\n\n\u003ch3\u003eIs professional installation recommended?\u003c\/h3\u003e\n\u003cp\u003eQualified commercial refrigeration personnel can verify motor rotation, blade mounting, clearance, airflow direction, and refrigeration-system operation during replacement.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Buy From Parts Direct Online?\u003c\/h2\u003e\n\n\u003cp\u003eParts Direct Online supplies commercial refrigeration fan blades, fan motors, guards, controls, heaters, gaskets, and related replacement components for service technicians, contractors, restaurants, supermarkets, cold-storage facilities, and foodservice operations throughout the United States.\u003c\/p\u003e","brand":"PartsDirectonline","offers":[{"title":"Default Title","offer_id":51370409525471,"sku":"14-FAN BLADE","price":68.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/3047\/0623\/files\/FANBLADE14INCH.webp?v=1789157020","url":"https:\/\/partsdirectonline.com\/products\/14-inch-ccw-fan-blade-27-degree-pitch-4-blade","provider":"PartsDirectonline","version":"1.0","type":"link"}